62
Electronic Controller
malfunction.
Replace Electronic
Controller.
Refer to
“electrical (
Electronic
Controller
)”
Water Level is Low.
Add Water.
Refer to
“Filling the heatMOr™
Outdoor Furnace initially with
Water.”
Creosote buildup on
firebox doorframe
causing improper door
seal.
Remove creosote from
doorframe.
Refer to
“Firedoor Frame”
Flipper assembly plate
not tight.
Tighten thumb nuts and
ensure a tight seal is
established.
Refer to
“steps to Maintain your
Blower and Flipper assembly”
Too little heat draw off
HEATMOR™.
Consult Dealer.
Contact your
Local Dealer
.
Circulating Pump not
Functioning.
Replace Pump.
Contact your
Local Dealer
.
no heat in
Building
Fire Out.
Light Fire.
Refer to
“Lighting your heatmor.”
Water level low.
Add Water.
Refer to
“Water Level Maintenance.”
Power loss.
Check Power Source.
Refer to
“electrical supply.”
Pump malfunction.
Replace Pump or
Cartridge.
Contact your
Local Dealer
.
Air trapped in water lines.
Bleed lines.
Contact your
Local Dealer
.
Malfunction of heating
appliances in building.
Repair, adjust or
replace.
Contact your
Local Dealer
.
PrOBLeM
cause
sOLutiOn
PrOceDure
Содержание 200 SSP
Страница 1: ...Outdoor Furnaces TM save these instructions...
Страница 8: ...3 EPA PHASE 2 HANGTAG MODEL 200 SSP...
Страница 9: ...4...
Страница 10: ...5 HEATMOR Stainless Steel PELLET BURNER Outdoor Furnace Model Chapter 1 Model 200 SSP...
Страница 77: ...72 Outdoor Furnaces...
Страница 79: ...74...