45
Heatilator • NNXT33-IFT, NNXT33L-IFT, NNXT36-IFT, NNXT36L-IFT Installation Manual • 2628-980 Rev. C • 8/20
IntelliFire Touch
®
Ignition System Wiring
• Wire the appliance junction box to 110-120 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT
wire
IPI controlled appliance junction box to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 8.2 IntelliFire Touch (IPI) Wiring Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
B. Wiring Requirements
FLAME SENSE
2090-012 (NG)
2090-013 (P)
IGNITER
ADAPTER
2326-131
I
S
6 PIN
2326-132
ORANGE
(PILOT)
GREEN
(MAIN)
RF MODULE 2326-120
IFT-RC400
REMOTE CONTROL
VALVE
2166-302 (NG)
2166-303 (P)
FAN
4031-057
IFT-WFM
WIFI MODULE
(OPTIONAL)
6V DC
BATTERY PACK
2326-134
RED
BLK
RED
JUMPER
WIRE
APPLIANCE
ON/OFF
CONTROL
BRN
BLK
JUNCTION BOX
110-120 VAC
2326-013
PVI-SLP-B
PVLP-SLP
WIRE HARNESS
PVI-WH10
PVI-WH20
PVI-WH40
PVI-WH60
PVI-WH80
PVI-WH100
(OPTIONAL POWER VENT)
PVV-SLP
2326-152
Wi-Fi MODULE 2326-137
(OPTIONAL)
BACK VIEW
TOP VIEW
FRONT VIEW
SIDE
VIEW
2326-130
2326-150
Figure 8.2 IntelliFire