34613 Rev F
22
01-03
NOVUS SERIES INSTALLATION INSTRUCTIONS
5. WIRING
a. Electronic Ignition
1) Appliance Requirements
This appliance requires a 110V AC supply from a wall switch to the appliance junction box for operation.
A wiring diagram is shown in Figure 41.
2) Optional Accessories Requirements
Wiring for optional accessories should be done now to avoid reconstruction.
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the ab-
sence of local codes, with National Electric Code ANSI/
NFPA 70-latest edition or the Canadian Electric Code
CSA C22.1.
CAUTION:
Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
Figure 41
Electronic Ignition Wiring Diagram
14-3 with ground Romex is the recommended wiring
to the appliance junction box. This allows each outlet
to power the appliance and fan independently.
Detailed picture of
junction box