34613 Rev F
12
01-03
NOVUS SERIES INSTALLATION INSTRUCTIONS
d. Assembling Vent Sections
Attach either a straight section from the rear vent
kit or an elbow, depending on your specific
installation.
Do not pack air spaces with insulation or other
material.
See Section F ASSEMBLING THE VENT
SECTIONS on page 18 for specific instructions on
each type of venting.
CAUTION:
Maintain minimum clearances or greater around
the vent system.
Note:
Horizontal runs will require the use of one
vent support (or metal plumbers strap) for every 3
of vent.
Figures 18 and 19 show how to install a typical
vent system. Use only pipe supplied and listed for
use with this appliance. See page 4 for a
description of listed components.
If the wall being penetrated is of noncombustible
materials, a 9 diameter hole is acceptable.
e. Installing the Interior Wall Shield
Whenever a combustible wall is penetrated, the
hole must be framed with an interior wall shield
as shown in Figures 20 and 21 on page 13. This
shield maintains minimum clearances and
restricts cold air infiltration.
Figure 18
Exterior Wall Hole
(Top Venting)
Figure 19
Exterior Wall Hole
(Rear Venting)
Note:
Exterior wall thickness must be a minimum
of 4 to a maximum of 23-1/2.
10
12
51
5/8
*
* This dimension includes 3/8 of rise for 18 horizontal
run. Any additional vertical sections of pipe will
increase this dimension accordingly.