background image

7056-138L • August 23, 2019

24

Heatilator EcoChoice WS18

www.heatilatorecochoice.com

Snap Disc

Magnet

Spade 

Connectors

Figure 24.1 

1. 

Disconnect power supply. Locate the snap disc 

bracket assembly at the bottom left rear corner of the 

appliance 

(Figure 24.1)

.

2.  A magnet holds the bracket to the appliance. Pull the 

bracket down away from the appliance to expose the 

snap disc.

3.  Pull the snap disc and spade connectors up and out of 

bracket as shown in 

Figure 24.2

.

4.  Using a Phillips head screw driver, remove the 2 screws 

from the snap disc and then remove the snap disc from 

the spade connectors. Replace with new snap disc and 

re-connect to spade connectors.

5.  Push the snap disc and spade connectors back inside 

bracket and re-attach the bracket to the appliance.

Figure 24.2

Snap Disc Location

C. Snap Disc Replacement

Figure 24.3

D. Door Handle Assembly

CAUTION

Do not

 over tighten lock nut. The door handle needs to 

move smoothly.

Locknut

Door Cross 

Section 

Latch Cam

3/8 inch 

Spacing 

Washers

Square Key

Door Handle 

Shaft

Spring 

Handle

Add up to 3 

washers on 

this side of 

the door

1. 

Install washer on door handle shaft.

2. 

Slide door handle through door.

3.  Add up to three washer as shown in 

Figure 24.3

 on the 

inside of the door.

4. 

Install key in groove.

5.  Align groove in latch cam with key; slide latch cam 

over shaft

6. 

Install locknut but do not over tighten, the handle needs 

to move smoothly.

7. 

Install handle turning in a counter-clockwise motion to 

desired location on door handle rod (

Figure 24.3).

Содержание ECO-ADV-WS18

Страница 1: ...d personnel Hearth Home Technologies recommends HHT Factory Trained or NFI certified professionals HOT SURFACES Glass and other surfaces are hot during operation AND cool down WARNING Hot glass and appliance will cause burns Do not touch glass until it is cooled Use leather gloves when reloading fuel NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room a...

Страница 2: ...DÉSIGNÉ DE L INSTALLATION LE CONTACT PEUT CAUSER DES BRÛLURES À LAPEAU GARDEZ LES MEUBLES ET LES MATÉRIAUX COMBUSTIBLES LOIN DE L ESPACE DÉSIGNÉ DE L APPAREIL VOIR L ÉTIQUETTE ET LES INSTRUCTIONS ATTENTION APPAREIL DE CHAUFFAGE DE PIÈCE DE TYPE DE COMBUSTIBLE SOLIDE POUR USAGE DANS LES MAISONS MOBILES UM 84 64 HUD Pour Usage Avec Bois Solide Seulement Installez et utilisez en accord avec les instr...

Страница 3: ... F Tube Channel Assembly Replacement 26 Install Guide 6 Getting Started 27 A Design and Installation Considerations 27 B Fire Safety 27 C Negative Pressure 28 D Tools And Supplies Needed 28 E Inspection of Appliance and Components 28 F Install Checklist 29 7 Dimensions and Clearances 30 A Appliance Dimensions 30 B Hearth Protection Requirements 31 C Clearances to Combustibles UL and ULC 32 8 Chimn...

Страница 4: ...g the product itself or refunding the verified purchase price of the product itself The maximum amount recoverable under this warranty is limited to the purchaser price of the product This warranty is subject to conditions exclusions and limitations as described below WARRANTY PERIOD Warranty coverage begins on the date of original purchase In the case of new home construction warranty coverage beg...

Страница 5: ...sure or drafting caused by tightly sealed constructions insufficient make up air supply or handling devices such as exhaust fans or forced air furnaces or other such causes 6 use of fuels other than those specified in the operation instructions 7 installation or use of components not supplied with the appliance or any other components not expressly authorized and approved by HHT 8 modification of the ...

Страница 6: ...ROL HIGH LOW REDUCE AIR CONTROL Set to desired heat output The appliance is ready for normal operation Warning Risk of Fire Close and securely latch the door after the fire has started and after refueling to prevent Spillage of smoke flame and carbon monoxide Spillage of sparks coals and logs Over firing DO NOT leave the appliance unattended with the door open Starting a fire may not require an open d...

Страница 7: ...anner inconsistent with operating instructions in this manual EPA Certification 777 EPA Certified Emissions 2 6 grams per hour LHV Tested Efficiency 80 4 HHV Tested Efficiency 74 4 EPA BTU Output 10 900 to 22 600 hr Peak BTU Hour Output 49 600 Vent Size 6 inches Firebox Size 2 0 cubic feet Maximum Wood Length 18 inches Ideal Wood Length 16 inches Fuel Seasoned Cord Wood Weighted average LHV effici...

Страница 8: ...ome Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating appliance without fully assembling all components Operating appliance without legs attached if supplied with appliance Do NOT Over fire If appliance or chimney connector glows you are over firing Any such action that may cause a fire hazard WARNING Fire Risk Hearth Home Technologies di...

Страница 9: ...urfaces are hot during operation AND cool down Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as appliance Alert children and adults to hazards of high temperatures High temperatures may ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable...

Страница 10: ...ay include one or more of the following Chimney connector or appliance glowing Roaring rumbling noises Loud cracking or banging sounds Metal warping Chimney fire 2 What To Do if Your Appliance is Over Firing Immediately close the door and air controls to reduce air supply to the fire If you suspect a chimney fire call the fire department and evacuate your house Contact your local chimney professio...

Страница 11: ...t that the flames be maintained and not allowed to go out This will ensure the cleanest possible fire If the flames tend to go out it is set too low for your burning conditions The air control located at the upper right hand corner is used to adjust for burn rates This is called the Burn Rate Air Control Figure 12 1 on page 12 3 Final Stage The final stage of burning is the charcoal stage This occ...

Страница 12: ... off until the burn is well established i e 30 minutes After loading the appliance with wood and starting the fire set the Burn Rate Air Controls to the desired setting by following the burn rate instructions below 2 High Burn Rate Maximum Heat 30 000 BTU hr Raise the Burn Rate Air Control all the way up until it stops top marker to a fully open position Be sure and monitor the fire closely while ...

Страница 13: ...ther the fire Stack the pieces of wood 1 2 inch to 1 inch apart near enough to keep each other hot but far enough away from each other to allow air flow between them 7 Once there is an established bed of coals set the Burn Rate Air Control to the desired setting following the instructions found in the Section Burn Rates and Operating Efficiency 8 If you have installed the optional blower please no...

Страница 14: ... Baffle Board MUST be in contact with the back of the firebox and even with each other in the front Ceramic Blanket Back of Firebox Baffle Board Baffle Retainer Bracket The baffle boards are FRAGILE Use extreme caution when loading firewood to prevent Cracking breaking or damaging the baffle boards DO NOT operate the appliance without baffle boards CAUTION WARNING Fire Risk Firebox damage due to i...

Страница 15: ...s completely Processed Solid Fuel Fire Logs NOT permitted for use in this appliance Hardwood vs Softwood Your appliance performance depends on the quality of the firewood you use Seasoned wood contains about 8 000 BTUs per pound Hard woods are more dense than soft woods Hard woods contain 60 more BTUs than soft woods Hard woods require more time to season burn slower and are harder to ignite Soft ...

Страница 16: ...st blower speed is obtained by turning the rheostat on then adjusting back towards OFF as far as possible without turning the blower off For a low blower speed turn the control knob clockwise as far as possible NOTE For maximum efficiency and lowest emissions when operating the blower in either the automatic or manual setting for the low and medium low burn settings leave the blower off until the ...

Страница 17: ...ioning Imbalances of the HVAC air handling system Upper level air leaks such as Recessed lighting Attic hatch Duct leaks To minimize the effects of negative air pressure Install the outside air kit with the intake facing prevailing winds during the heating season Ensure adequate outdoor air for all combustion appliances and exhaust equipment Ensure furnace and air conditioning return vents are not...

Страница 18: ...th salt driftwood May generate carbon monoxide if burn material other than wood May result in illness or possible death ISSUES SOLUTIONS Odor from appliance When first operated this appliance may release an odor for the first several hours This is caused by the curing of the paint and the burning off of any oils remaining from manufacturing Metallic noise Noise is caused by metal expanding and con...

Страница 19: ... cap blockage and creosote build up Firebrick Ash Removal WEEKLY or After Every 25 Loads of Wood Ashes must be cool before you can dispose of the ashes in a non combustible container Firebrick is designed to protect your firebox After ashes are removed inspect the firebrick and replace firebricks that are crumbling cracked or broken Door Glass Assemblies WEEKLY or After Every 25 Loads of Wood Keep...

Страница 20: ... which combine with expelled moisture to form creosote The creosote vapors condense in the relatively cool chimney flue of a newly started or a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote creates an extremely hot fire which may damage the chimney or even destroy the house The chimney connector and chimney should be inspected once every 2...

Страница 21: ...he Burn Rate Air Control all the way open for 30 45 minutes should remove the built up coating Clean all the fingerprints and oils from plated surfaces BEFORE firing the appliance for the first time If not cleaned properly before lighting your first fire the oils can cause permanent markings on the plating After the plating is cured the oils will not affect the finish and little maintenance is req...

Страница 22: ... flue before starting fire refer to Building a Fire Section Check for adequate vent height refer to Chimney Height Section Open window towards the wind Wood condition is too wet too large Use dry seasoned wood refer to Seasoned Wood Section Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to Building a Fire Section Flue blockage such as bird...

Страница 23: ...heat resistant glass which can only be broken by impact or misuse WARNING Injury Risk Use only glass specified in manual DO NOT REPLACE with any other material Handle glass assembly with care When cleaning glass Glass Assembly CAUTION Avoid striking scratching or slamming glass Do NOT clean glass when hot Do NOT use abrasive cleaners Use a hard water deposit glass cleaner on white film Use commerc...

Страница 24: ...nectors 5 Push the snap disc and spade connectors back inside bracket and re attach the bracket to the appliance Figure 24 2 Snap Disc Location C Snap Disc Replacement Figure 24 3 D Door Handle Assembly CAUTION Do not over tighten lock nut The door handle needs to move smoothly Locknut Door Cross Section Latch Cam 3 8 inch Spacing Washers Square Key Door Handle Shaft Spring Handle Add up to 3 wash...

Страница 25: ...th the ceramic blanket still in place slide one baffle piece over the top of other one and pull out top piece through the door opening and then remove bottom baffle piece Figure 25 1 4 Remove the ceramic blanket 5 Re install the ceramic blanket and smooth out the blanket 6 Slide the baffle pieces one piece at a time underneath the blanket Be sure the baffle boards are even with the front manifold ...

Страница 26: ... Replacement NOTE Soak the bolts with penetrating oil for at least 15 minutes before trying to remove them Replacing Tube Channel Assembly 5 Slide the tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 6 Make sure tube channel assembly is flush against the side of the appliance and secure with chann...

Страница 27: ...out restrictions installation inspection and permits CAUTION NOTICE Hearth Home Technologies assumes no responsibility for the improper performance of the appliance system caused by Inadequate draft due to environmental conditions Down drafts Tight sealing construction of the structure Mechanical exhausting devices Over drafting caused by excessive chimney heights Ideal performance is with height ...

Страница 28: ...t can be strongest in lower levels of the house Causes include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water appliances and other combustion appliances Clothes dryers Location of return air vents to furnace or air conditioning Imbalances of the HVAC air handling system Upper level air leaks such as Recessed lighting Attic hatch Duct leaks To minimize the ...

Страница 29: ...rom inside under the appliance and given to the party responsible for use and operation Hearth Home Technologies recommends the following Photographing the installation and copying this checklist for your file That this checklist remain visible at all times on the appliance until the installtion is complete Comments Further description of the issues who is responsible Installer Builder Other Trade...

Страница 30: ... 500 mm 21 11 16 in 550 mm 29 in 736 mm 14 13 16 in 376 mm 9 9 16 in 242 mm 13 13 16 in 350 mm 19 1 16 in 484 mm 9 5 16 in 236 mm 26 1 2 in 673mm 24 1 8 in 612mm 6 11 16 in 169mm 10 5 8 in 269mm 19 1 16 in 484mm 22 13 16 in 579mm 23 1 4 in 591mm C L Figure 30 2 Top View 7 Dimensions and Clearances A Appliance Dimensions NOTE Flue Collar size is 6 inch 152mm diameter ID ...

Страница 31: ...fied High temperatures or hot embers may ignite concealed combustibles Figure 31 1 Figure 31 4 Figure 31 3 Figure 31 2 Figure 31 5 Figure 31 6 Corner hearth pad dimensions with single wall pipe Corner hearth pad dimensions with double wall pipe USA minimum flat wall hearth pad dimensions Canada flat wall hearth pad dimensions with double wall horizontal venting this dimension will vary depending i...

Страница 32: ...w Off Top of Appliance Through Back wall Single Wall Pipe 11 75 298 8 203 18 25 464 8 5 216 3 5 89 13 330 54 25 1378 Double Wall Pipe 11 75 298 8 203 18 25 464 8 5 216 3 76 12 5 318 54 25 1378 10 254 For alcove only Six inch diameter listed Double wall air insulated connector pipe with UL103 HT listed factory built Class A chimney or masonry chimney Maximum depth of Alcove shall be no more than 48...

Страница 33: ...stall through the warm space enclosed by the building envelope This helps to produce more draft especially during lighting and die down of the fire Penetrate the highest part of the roof This minimizes the affects of wind turbulence and down drafts Consider the appliance location in order to avoid floor and ceiling attic joists and rafters Locate termination cap away from trees adjacent structures...

Страница 34: ...a level and or when there are other factors that affect flue draft B Chimney Termination Requirements Follow manufacturer s instructions for clearance securing flashing and terminating the chimney Figure 34 1 34 2 Must have an approved and Listed cap Must not be located where it will become plugged by snow or other material Must terminate at least 3 feet 91cm above the roof and at least 2 feet 61c...

Страница 35: ...L 103 HT 2100 F or ULC S629M Must use components required by the manufacturer for installation Must maintain clearances required by the manufacturer for installation Refer to manufacturers instructions for installation D Chimney Height Rise and Run This product was designed for and tested on a 6 inch 152mm chimney 14 to 16 feet 420 480cm high includes appliance height measured from the base of the...

Страница 36: ...ling or minimum recommended by chimney connector manufacturer Figure 36 2 Instructions 1 Open inside wall at proper height for the chimney connector to entry the masonry chimney Figure 36 2 2 Entry hole to masonry chimney must be lined with an 8 inch 203mm minimum diameter clay liner or equivalent secured with refractory mortar 3 Construct a 17 inch x 17 inch 432mm x 432mm outside dimension frame ...

Страница 37: ...nents Chimney Connector Single wall connector or appliance pipe This must be at least 24 gauge mild steel or 26 gauge blue steel The sections must be attached to the appliance and to each other with the crimped male end pointing toward the appliance All joints including the connection at the flue collar should be secured with 3 sheet metal screws Make sure to follow the minimum clearances to combu...

Страница 38: ...akage around windows and under doors In homes that have tightly sealed doors and windows an outside air source is highly recommended An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap For Floor Installa tions Remove Circular Knock Out in Base of Pedestal Wire Tie Remove Circular Knock Out in Base of Pedestal and Seal the Pedestal with Non combustible ...

Страница 39: ...wer speed control for this appliance is adjusted at the factory and normally does not require further adjustment NOTE When the speed control is turned clockwise it will click on to high speed Continue to turn the speed control clockwise to decrease the speed At full clockwise the blower should blow gently but should not stop MANUAL Over rides the Snap Disc AUTO Fan will turn ON OFF Automatically b...

Страница 40: ...replace must meet UM 84 HUD requirements for outside combustion air supply to the fireplace fire chamber and the chimney must be listed to UL103 HT or a listed UL 1777 full length six inch 152mm diameter liner must be used It must be equipped with a spark arrestor cap and the outside air must be installed on the insert 5 Refer to pages 30 32 of this manual for clearance to combustibles and floor p...

Страница 41: ...7056 138L August 23 2019 41 Heatilator EcoChoice WS18 www heatilatorecochoice com 11 Reference Materials A Service Maintenance Log Date of Service Performed By Description of Service ...

Страница 42: ...7056 138L August 23 2019 42 Heatilator EcoChoice WS18 www heatilatorecochoice com Date of Service Performed By Description of Service ...

Страница 43: ...ce WS18 www heatilatorecochoice com Service Parts Beginning Manufacturing Date Mar 2010 Ending Manufacturing Date Active Part number list on following page ECO ADV WS18 Free Standing Wood Stove 1 2 3 4 5 6 7 8 9 10 11 12 13 14 08 18 B Exploded View ...

Страница 44: ...on Channel SRV7056 147 8 Retainers Tube Support SRV7056 132 9 Pedestal Assembly SRV7056 003 10 OA Cover Plate SRV7044 217 11 Side Panel Right SRV7056 117 12 Tube Channel Cover SRV7056 125 13 Tube Channel Assembly SRV7056 006 Y 14 Burn Rate Control 14 1 Burn Rate Control Assembly SRV7056 008 Y 14 2 Spring Handle 1 4 Black SRV7000 614 Y 14 3 Door Gasket 7033 282 Y 14 4 Inlet Door Assembly SRV7056 00...

Страница 45: ...Box W Switch SRV7000 194 Y Component Pack 7033 051 Magnet Round SRV7000 140 Y Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Wire Harness 7033 262 Component Pack SRV7056 013 Contains Screws Handle Spring Handle 1 4 Black Warranty Card OA Cover Plate Manual Ef ciency Label EPA Label and Startup and Maintenance Guide Outside Air Kit OAK ACC Outside Air Collar Assembl...

Страница 46: ...g and maintenance instructions included Read understand and follow these instructions for safe installation and operation Leave this manual with party responsible for use and operation of this appliance We recommend that you record the following pertinent information for your heating appliance Date purchased installed Serial Number Location on appliance Dealership purchased from Dealer Phone 1 Not...

Отзывы: