Figure 12.16 Air Shutter
L. Air Shutter Setting
This appliance has an adjustable air shutter (which controls
the primary air mixture) that can be accessed from under the
valve compartment located under the
fi
rebox assembly (see
Figure 12.16). If your installation has more than the minimum
vertical vent length, adjustments to the air shutter may be re-
quired to obtain the optimal
fl
ame appearance.
A quali
fi
ed
installer should adjust this at the time of installation.
It takes 16 full turns of the shutter adjustment handle to move
the air shutter from fully open to fully closed. In the event
of soot accumulation inside your appliance, the air shut-
ter should be opened further. When the shutter adjustment
handle is all the way
down
, the air shutter is in the
closed
position. When the shutter adjustment handle is all the way
up
, the air shutter is in the fully
open
position.
Install Firescreen Assembly
• Thread screen onto screen rod making sure to thread all
screen rings.
• Hold the mesh
fi
rescreen in one hand until you get the rod
inserted into the side columns to prevent the mesh from
falling off the rod.
• Insert one end of screen rod into the hole located in the
column as far as it will go. See Figure 12.15
Figure 12.15 Insert Rod Into Side Columns
• Flex the rod and insert it into the hole in the column on
the other side.
• Hook the center of the rod into the screen rod tabs (shown
in Figure 12.10).
• Spread
fi
rescreen to the edges of the
fi
rebox opening.
• Hairpin clips are shipped in place in a hole in the bottom
of each column. After the screen is in place, squeeze clips
and remove from holes. Thread clip through screen (one
on each side), squeeze slip and re-insert into holes.
Note:
The
fl
oor cover in the bottom front of the
fi
replace
may be covering the UL labels. It is loose and can be
removed/replaced.
Содержание Direct Vent Gas Appliance CD4236MILR
Страница 69: ...Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 69 This page intentionally left blank ...
Страница 80: ...80 Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 This page intentionally left blank ...
Страница 81: ...Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 81 This page intentionally left blank ...
Страница 82: ...82 Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 This page intentionally left blank ...