E. Installing Vertical Termination Baf
fl
e
1.
Remove the glass (refer to Section 12.H.) to access the
fi
rebox and 5 in. inner
fl
ue.
2.
Fold the baf
fl
e (Figure 5.17) to an approximate 90° angle
(see Figure 5.18).
3.
Squeeze the open end of the bent baf
fl
e with one hand.
Insert the baf
fl
e bent side up into the inner
fl
ue so that
the bottom of the baf
fl
e is above the bead on the inside
of the collar. See Figure 5.19.
4.
Release pressure on the baf
fl
e so that it is wedged against
the sides of the
fl
ue collar. See Figure 5.20.
5.
Replace the glass (refer to Section 12.H.).
6.
Start the appliance.
Note:
For vertically terminated installations only.
Figure 5.17 Flat Baf
fl
e
Figure 5.18 Baf
fl
e Bent to 90° Angle
Figure 5.19 Placing the Baf
fl
e
Figure 5.20 Baf
fl
e in Place
Note:
If installing a vertical vent/termination run off the
top or rear of the appliance, the vertical termination baf
fl
e
supplied with the appliance may be used.
Содержание Direct Vent Gas Appliance CD4236MILR
Страница 69: ...Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 69 This page intentionally left blank ...
Страница 80: ...80 Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 This page intentionally left blank ...
Страница 81: ...Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 81 This page intentionally left blank ...
Страница 82: ...82 Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 This page intentionally left blank ...