A. Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other
combustible projections above the top front edge of the appliance.
B. Facing Material
Measured from top of hood (in inches)
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
5
5-1/2
6-1/4
7
7-3/4
8-1/2
9-1/4
10
10-3/4
11-1/2
12-1/4
13
13-3/4
14-1/2
15-1/4
16
30 in. minimum
to ceiling
Figure 11.1 Clearances to Mantels or other Combustibles above
Appliance.
1 in. (25 mm) min.
to perpendicular wall
A
3-1/2 in. (89 mm) min.
from fireplace opening
to perpendicular wall
B
48 in.
(1219 mm)
max.
Mantel Leg or
Perpendicular Wall
Top of
Appliance
Drywall
A
B
Figure 11.2 Mantel Leg or Wall Projections
(Acceptable on both sides of opening)
0 in.
0 in.
0 in.
Finish wall material may be
combustible - Top and Sides
High Temperature Sealant (300° F/149° C min.)
Top and Side Seal Joint
Figure 11.3 Noncombustible Facing Diagram
11
11
Finishing
Fire Risk
Finish all edges and fronts to clearances and
speci
fi
cations listed in manual.
WARNING
• Black metal appliance front may be covered with non-
combustible material only.
• Do NOT overlap combustible materials onto appliance
front.
• Install combustible materials only up to speci
fi
ed
clearances on top, front and sides.
• Seal joints between the
fi
nished wall and appliance
top and sides using only a 300° F minimum sealant.
Fire Risk
Explosion Risk
• Facing
and/or
fi
nishing materials must never
overhang into the glass opening.
• Overhanging materials may ignite.
• May interfere with proper operation of glass
assembly.
WARNING
Содержание Direct Vent Gas Appliance CD4236MILR
Страница 69: ...Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 69 This page intentionally left blank ...
Страница 80: ...80 Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 This page intentionally left blank ...
Страница 81: ...Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 81 This page intentionally left blank ...
Страница 82: ...82 Heatilator Caliber Mesh CD Series SIT Valve 4040 849 Rev H 11 07 This page intentionally left blank ...