22
Heatilator • Caliber Mesh CD Series-SIT Valve • 4040-849 Rev H • 11/07
12 ft (3.66 m) min.
60 ft (18.29 m) max.
0 min.
6 ft (1.83 m) max.
Maximum horizontal
run is 100% of
vertical, but cannot
exceed 26 ft (7.92 m)
Rear Vent—Vertical Termination—Two Elbows
Figure 5.15 Vertical Termination - Two Elbows
Rear Vent—Vertical Termination—One Elbow
12 ft (3.66 m) min.
60 ft (18.29 m) max.
0 min.
6 ft (1.83 m) max.
Figure 5.14 Vertical Termination - One Elbow
Note: Subtract 3 ft (914 mm) from the total horizontal
measurement
for each 90° elbow installed horizontally.
Subtract 1-1/2 (457 mm) ft from the total horizontal
measurement
for each 45° elbow installed horizontally.
Note:
If installing a vertical
vent/termination run off the
rear of the appliance, the
vertical termination baffle
supplied with the appliance
may be used. See Section E.
Note:
If installing a vertical vent/termination
run off the rear of the appliance, the vertical
termination baf
fl
e supplied with the appliance
may be used. See Section E.