Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07
9
Fire Risk
Odor Risk
• Install appliance on hard metal or wood
surfaces extending full width and depth
of appliance.
• Do NOT install appliance directly on
carpeting, vinyl, tile or any combustible
material other than wood.
WARNING
C. Clearances
30 in.
(762 mm)
to ceiling
D
0 in.
0 in. TO LEVEL
OF STANDOFFS
Combustible Object
36 in.
(914 mm)
Combustible flooring may be installed next
to the front of the appliance.
C
B
A
1/2 in. (13 mm)
1/2 in.
(13 mm)
Drywall
0 in.
Figure 3.2 Clearances to Combustibles
Model
A
Rough
Opening
(Width)
B
Rough
Opening
(Height)
C
Rough
Opening
(Depth)
D
Rough
Opening
(DVP Pipe)
CNXT4236
in.
42
38-3/4
23-1/2
10
mm
1067
984
597
254
CNXT4842
in.
48
38-3/4
23-1/2
10
mm
1219
984
597
254
Note: