Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07
45
Shock Risk
• Replace damaged wire with type 105°
C rated wire.
• Wire must have high temperature
insulation.
WARNING
E. WSK-MLT Multifunction Wall Switch
The WSK-MLT multifunctional wall switch is designed to
control
fl
ame height, blower speed and auxilary functions on
your gas
fi
replace. For models equipped with the intelli
fi
re
system (*IPI), the cold climate function can control the pilot
fl
ame as well. The wall switch is equipped with thermostat
functions which can automatically control the temperature
in the room in which it is installed. An auxiliary function pro-
vides 110-120 VAC source for added features the
fi
replace
may have installed. Electrical ratings for the control box are
110 VAC, 60 Hz, and is required for operation of this de-
vice.
Precautions
This remote is tested and safe when installed in accordance-
with this installation manual. It is your responsibility to read
all instructions before starting installation and to follow these
instructions carefully during installation. Do not install any
components that may be damaged. Do not modify, disas-
semble, or substitute any of the components included with
this kit. Installation of this unit must be done by a quali
fi
ed
service technician.
Placement of this wall switch may affect performance or ac-
curacy of the automatic (thermostat) control. An assessment
of the space should be done prior to installation for optimal
performance. See “Determine Location” for recommenda-
tions.
Determine Location
Determine the location for the wall switch. The chosen loca-
tion should provide an accessible location in the same space
as the gas
fi
replace. Never place this unit in a separate
room. The control wire supplied with this unit is 17 ft (5.2 m)
in length. The distance from the
fi
replace to the switch may
be lengthened provided that the wire used never exceeds
50 ft, and that the distance from the
fi
replace to the switch
never exceeds 30 ft.
The switch should be mounted into a listed electrical junc-
tion box. The junction box should be dedicated to this wall
switch. Never install this wall switch into a junction box that
is shared with other electrical service or devices. If possible,
install this unit on an interior wall of the residence at a rec-
ommended height of 5 ft from the
fl
ooring. Should the switch
be installed on an exterior wall, be certain wall insulation is
kept intact and not damaged or dislodged during the instal-
lation of the electrical junction box.
For exterior wall installations, it is recommended that the
junction box be sealed with caulking material. This will mini-
mize heat loss through this location and improve the accu-
racy of the automatic (thermostat) operation.
All wiring should be done by a quali
fi
ed electrician and shall
be in compliance with local codes and with the
National
Electric Code ANSI/NFGA No. 70- current
(in the United
States), or with the current
CSA C22.1 CANADIAN ELEC-
TRIC CODE
(in Canada).
Note:
The electrical junction box provided with the
fi
replace
must be wired with 110 VAC before installing this kit.