Heatilator • Caliber CNXT Series • 4047-132 Rev P • 11/07
49
I. WSK-MLT Operating Instructions
The ON/OFF rocker switch in the
fi
replace (located near the
gas valve) must be in the “OFF” position for use with the
WSK-MLT system. The ON/OFF rocker switch will NOT func-
tion with this device on Intelli
fi
re (IPI) models except during a
power outage. The ON/OFF rocker switch will only be used
to control the
fi
replace in a no-power condition.
After all connections are made and the control box is ground-
ed, plug power cord into the
fi
replace junction box. The wall
switch will be functional at this time.
For IPI system, refer to “Operation Under Battery Power” for
instructions.
Note:
The temperature displayed by the wall switch may
take up to 30 minutes to stablize on initial power-up.
Note:
Check control box and assure switch is in the “OFF”
position. This switch is only used on Intelli
fi
re (IPI) control
systems under battery operation.
J. Setting Flame Height/Manifold Pressure
(To be done by a quali
fi
ed service technician.) Upon ini-
tial power-up of this device, valve pressure must be set for
fl
ame adjustment.
• Loosen output pressure tap on valve and connect with
pressure manometer.
• Press
fl
ame button once (see Figure 10.8);
fi
replace will
light with
fl
ames on high.
• Turn solenoid clockwise to increase pressure,
counterclockwise to decrease pressure until manifold
pressure on high is 3.5 in. water column for natural gas
(NG), 10.0 in. water column for propane (LP).
• Once pressure is achieved sping jam nut on solenoid
step tight against regulator face to prevent rotation. Do
not overtighten.
• Press
fl
ame button twice to turn
fi
replace off.
• Remove manometer tube and tighten or close pressure
tap. Use a commercially available, non-corrosive leak
check solution to carefully check the pressure tap for
leaks. Be sure to rinse off all leak check solution following
testing.
Figure 10.8 Wall Switch
Содержание CNXT4236IH CNXT4842IH
Страница 88: ...88 Heatilator Caliber CNXT Series 4047 132 Rev P 11 07 This page intentionally left blank...
Страница 89: ...Heatilator Caliber CNXT Series 4047 132 Rev P 11 07 89 This page intentionally left blank...
Страница 90: ...90 Heatilator Caliber CNXT Series 4047 132 Rev P 11 07 This page intentionally left blank...