Heat & Glo • FDN-4-SS, FDN-5-SS, FDN-6-SS, FDN-7-SS Installation Manual • 16400-9800 Rev. H • 11/19
6
2 - FIREPLACE SPECIFICATIONS
1” [25]
NO COMBUSTIBLE
MATERIAL WITHIN
1” [25] OF SIDES AND
BACK OF FIREPLACE
NO COMBUSTIBLE MATERIAL
WITHIN 6” [152] OF THE TOP
OF THE FIREPLACE
NO COMBUSTIBLE
MATERIAL WITHIN 1” [25]
OF B-VENT FLUE
OTHER CLEARANCES:
DO NOT PLACE ON CARPET, VINYL OR SOFT SURFACES.
A COMBUSTIBLE MANTEL MAY BE PLACED AT THE TOP OF THE GLASS VIEWING AREA. DO NOT OVERLAP GLASS.
A COMBUSTIBLE HEARTH EXTENSION MAY BE USED AT THE BOTTOM OF GLASS VIEWING. DO NOT OVERLAP GLASS.
* MINIMUM DISTANCE RECOMMENDED FROM FRONT OF APPLIANCE FOR SERVICE ACCESS = 24 IN. [610 mm].
COMBUSTIBLE
FRAMING AND
FINISHING MATERIAL
ALLOWED ON THE FACE
OF THE FIREPLACE
BELOW THE BOTTOM
VIEWING EDGE ONLY.
NO COMBUSTIBLE
MATERIAL WITHIN 1” [25]
OF SIDES AND BACK OF
FIREPLACE
1” [25]
6” [152]
FRONT*
Figure 2B
WARNING: NON-COMBUSTIBLE ZONE: USE ONLY NON-COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF
FIREPLACE. DO NOT USE WOOD, SHEETROCK, ETC., IN THIS ZONE. SEE FIGURE 2B.
NOTE: OTHER CLEARANCES APPLY. ALL CLEARANCES MUST BE MAINTAINED.
Refer to Section 5 (Non-Combustible Zone) and Section 10 (Finishing) for more information.
SPECIFICATIONS TABLE
Model #
B-VENT
OA
REG PV
IN-LINE PV
BTU’S
NG
ORIFICE
PROPANE
ORIFICE
FDN-4-SS
4X2 SINGLE SIDED
8”
10”
PVK-45
PVI-45
60,000
(3X) #43
(3X) #55
FDN-5-SS
5X2 SINGLE SIDED
8”
10”
PVK-45
PVI-45
80,000
(4X) #43
(4X) #55
FDN-6-SS
6X2 SINGLE SIDED
10”
10”
PVK-67
PVI-67
100,000
(5X) #43
(5X) #55
FDN-7-SS
7X2 SINGLE SIDED
10”
10”
PVK-67
PVI-67
120,000
(6X) #43
(6X) #55
B. CLEARANCES
CLEARANCES
From unit left & right sides
1"
25mm
To flooring under fireplace
0
0
Unit top to ceiling
6"
152mm
Unit side to adjacent sidewall
1"
25mm
From appliance front*
*See note below