19
Heat & Glo • FDN-4-SS, FDN-5-SS, FDN-6-SS, FDN-7-SS Installation Manual • 16400-9800 Rev. H • 11/19
Available Power Venting
A power vent (PVK-45 or PVK-67) is approved for use with
this appliance. It is crucial that all B-Vent pipe and elbow joints, and the longitudinal seam
are sealed using a high temperature RTV Silicone and/or foil tape.
NOTE: All pipe and elbow joints must be sealed. This includes the longitudinal seam on the pipe.
High Temp RTV Silicone and/or foil tape MUST be used on each joint/seam.
Failure to do so may cause lack of vacuum and may not trigger the vacuum switch.
MODEL
PVK-45
PVK-67
Fan Type
Axial vane
Axial vane
Motor Type
Totally enclosed,
variable speed,
Class H
Totally enclosed, variable
speed, Class H
Voltage (VAC)
1 x 120
1 x 120
RPM
1600
1600
CFM
950
1400
Amperage (Amps)
1.2
1.4
Motor Output HP (kW)
1/9 (0.08)
1/7 (0.1)
Weight lbs (kg)
37 (17)
47 (21)
Dimension A in. (mm)
11.5 (292)
13.1 (334)
Dimension B x B in.(mm)
14.3 (364)
16.6 (422)
Dimension C in. (mm)
13.5 (344)
15.5 (395)
Dimension D in. (mm)
3.3 (85)
3.9 (100)
Dimension E in. (mm)
11.6 (294)
13.5 (342)
Temperature Rating-Intermittent
575 °F / 300 °C
575 °F / 300 °C
Temperature Rating-Continuous
482 °F / 250 °C
482 °F / 250 °C
Figure 8A.2
HOLE SPACING
13-1/4 IN.
337 mm
INSIDE FLANGE
14-1/2 IN.
368 mm
HOLE DIAMETER
3/8 IN.
10 mm
HOLE DIAMETER
3/8 IN.
10 mm
HOLE SPACING
14-11/16 IN.
373 mm
INSIDE FLANGE
17-1/8 IN.
435 mm
Figure 8A.3 8 Inch Chimney Collar Dimensions (PVK-45)
Figure 8A.4 10 Inch Chimney Collar Dimensions (PVK-67)
Chimney Collar Dimensions
A chimney collar is included for use with the PVK-45 and PVK-67. The chimney collar is used to attach the PVK power vent. Figures 8A.3 and 8A.4
show the dimensions of the chimney collar.