57
Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Installation Manual • 2310-970 Rev. L • 2/16
= NO FASTENERS IN THIS AREA
= 3/4 INCH MAX. LENGTH FASTENERS IN THIS AREA
2 IN.
1/2 IN.
Figure 10.1 Screw Length Requirements
WARNING! Risk of Injury! Risk of Explosion! Install fasteners as instructed.
• Gas train could be damaged causing a gas leak.
• Electrical components could be damaged causing electrical shock.
• LED’S could be damaged.
• Glass installation could be obstructed.
Note:
It is acceptable to use a high temperature silicone
sealant to adhere drywall to lower access cover panel.
SHEET ROCK WALL
= 1/2 IN. SHEETROCK
SHEETROCK STOPS AT RETURN BEND
= APPLIANCE OPENING