Installation Standard Work Checklist
Appliance Install Sections 3 , 6 and 11
YES IF NO, WHY?
Veri
¿
ed that the chase is insulated and sealed. (Pg. 17)
___________________________
Veri
¿
ed clearances to combustibles. (Pg. 12)
___________________________
Fireplace is leveled and secured. (Pg. 27)
___________________________
Barrier glass installed correctly. “THIS SIDE OUT” is readable. (Section 11) ___________________________
Venting/Chimney/PowerFlow™ Heat Management Sections 4,5 and 7
Venting con
¿
guration complies to vent diagrams. (Section 4)
___________________________
Venting installed, locked, secured in place and sealed with correct clearance.
___________________________
Firestops installed. (Section 5)
___________________________
Attic insulation shield installed. (Section 5)
___________________________
Exterior wall/Roof
À
ashing installed and sealed. (Section 7)
___________________________
Terminations installed and sealed. (Section 7)
___________________________
PVI-SLP or PVLP-SLP power vent installed with correct baf
À
e setting.
___________________________
HEAT-ZONE-PRIMO and/or HEAT-OUT-PRIMO installed and vented
properly; complies with vent run min./max. requirements in installation manual. ___________________________
Electrical Section 8 (Pg 46-50)
Unswitched power (110-120 VAC) provided to the appliance.
___________________________
LED switch wires properly installed.
___________________________
If only HEAT-OUT-PRIMO is installed: Wall switch plate and toggle switch not installed. ___________________________
Gas Section 9 (Pg 51-55)
Proper appliance for fuel type.
___________________________
Was a conversion performed?
___________________________
Leak check performed and inlet pressure veri
¿
ed.
___________________________
Veri
¿
ed proper air shutter setting for installation type.
___________________________
Verify that the gas access plate remains installed. (Pg 54) ___________________________
Finishing Section 10 (Pg 56-75)
1/2 inch sheetrock used as recommended. ___________________________
Veri
¿
ed all clearances meet installation manual requirements.
___________________________
Mantels and wall projections comply with installation manual requirements.
___________________________
Granite or Clean Face
¿
nishing complete and complies with clearance
requirements in installation manual. ___________________________
Barrier glass properly installed. ___________________________
Appliance Setup Section 11 (Pg 76-78)
All packaging and protective materials removed (inside & outside of appliance).
___________________________
Glass or granite panels and media installed correctly.
___________________________
Firebox glass assembly installed and secured.
___________________________
Accessories installed properly.
___________________________
Manual bag and all of its contents are removed from inside/under
the appliance and given to party responsible for use and operation.
___________________________
Started appliance and veri
¿
ed no
gas leaks exist.
___________________________
Multicolored LED lights work in all switched positions.
___________________________
Customer:
Lot/Address:
Model (circle one): PRIMO48 PRIMO60 PRIMO72
PRIMO48ST PRIMO60ST PRIMO72ST
Date Installed:
Location of Fireplace:
Installer:
Dealer/Distributor Phone #
Serial #:
Comments:
Further description of the issues, who is responsible (Installer/ Builder/ Other Trades, etc) and corrective
action needed _____________________________________________________________________________________
_________________________________________________________________________________________________
Comments Communicated to party responsible ____________________ by ______________________on ___________
(Builder / Gen. Contractor/) (Installer)
(Date)
2310-972 Rev. C 2/16
Î
= Contains updated information.
Hearth & Home Technologies recommends the following:
• Photographing the installation and copying this checklist for your
¿
le.
• That this checklist remain visible at all times on the appliance until the installation is complete.
This standard work checklist is to be used by the installer in conjunction with, not instead of, the instructions contained in this
installation manual.
WARNING! Risk of Fire or Explosion!
Failure to install appliance according to these instructions can
lead to a
¿
re or explosion.
ATTENTION INSTALLER:
Follow this Standard Work Checklist