DESN 512448
PLEASE NOTE: IT IS ADVISABLE TO
CHECK THE ACTUAL SIZE/WIDTH
OF YOUR APPLIANCE BEFORE
FINALLY FIXING ANY KITCHEN
UNITS, SINCE ENAMELLED CAST
IRON CAN VARY IN SIZE
DIMENSIONS IN MM
5
Gas Inlet
1/2” NPT
Unpacked Appliance Weight
- 326 Kg (719 lbs)
Electrical Supply
115 V 60 Hz
Natural Gas
Propane
Appliance Inlet
10” w.g.
15” w.g.
Pressure (MAX.)
Burner Pressure
-
0.044 w.g. (± 0.012” w.g.)
-
0.044 w.g. (± 0.012” w.g.)
(NEGATIVE)
(non-adjustable)
(non-adjustable)
Max Flue Temp.
445ÞF
450ÞF
CO
0 - 50 ppm
0 - 50 ppm
CO
2
%
8.2% - 9.9%
9.4% - 10.8%
Heat Input
50,000 Btu/hr
50,000 Btu/hr
TECHNICAL DATA
Содержание Classic HL-CKNG
Страница 14: ...Installation Instructions FIG 7 14 TERMINAL STRIP CONNECTIONS ...
Страница 17: ...Users Guide 17 ...
Страница 37: ...Electrical Controls CONTROL CIRCUIT EXTERNAL TERMINAL STRIP CONNECTIONS 37 ...
Страница 45: ...Fault Finding WIRING DIAGRAM BURNER ONLY FIG 31 45 ...
Страница 49: ...Trouble Shooting 49 ...
Страница 51: ...51 ...