Replacement of parts (Electrical Controls)
FIG. 28
FIG. 29
DESN 511444
DESN 511737
THERMOSTAT
OVERHEAT
THERMOSTAT
COOKER
TIMER
TO FIT NEW FLUE SAFETY DEVICE
ENSURE THAT ALL ELECTRICAL SUPPLIES TO THE
APPLIANCE HAVE BEEN TURNED OFF.
SEE FIG. 28
Follow instructions in section BURNER ACCESS Steps 1
to 3.
1.
Remove 2 screws securing flue safety device bracket.
2.
Withdraw thermostat and remove (2) push on
connectors.
3.
Remove thermostat securing nut.
4.
Remove phial guide bracket from tube.
5.
Pull phial from securing clip and withdraw.
6.
Fit replacement device and assemble in reverse order
of removal ensuring the phial is correctly located
within the tube and guide bracket is located under the
safety device fixing bracket.
RESET
BUTTON
43
Содержание Classic HL-CKNG
Страница 14: ...Installation Instructions FIG 7 14 TERMINAL STRIP CONNECTIONS ...
Страница 17: ...Users Guide 17 ...
Страница 37: ...Electrical Controls CONTROL CIRCUIT EXTERNAL TERMINAL STRIP CONNECTIONS 37 ...
Страница 45: ...Fault Finding WIRING DIAGRAM BURNER ONLY FIG 31 45 ...
Страница 49: ...Trouble Shooting 49 ...
Страница 51: ...51 ...