Replacement of parts (Electrical Controls)
BEFORE REMOVING SERVICE ACCESS COVERS
ENSURE THAT ALL ELECTRICAL SUPPLIES TO THE
APPLIANCE HAVE BEEN TURNED OFF.
SEE FIG. 25
1.
Remove the controls door and place in a safe position.
2.
Remove thermostat control knob.
3.
Remove the (2) cover panel fixing screws.
4.
Remove cover panel. It will be necessary to
disconnect the push on tags from the timer, noting
position of wiring.
5.
Remove the (4) control panel fixing screws.
6.
Tilt the chassis forwards from the top and lift out. To
fully access the rear of the control chassis, the oven
thermostat capillary and overheat thermostat capillary
should be removed from the oven. Follow instructions
in section ‘TO FIT NEW OVEN CONTROL
THERMOSTAT’, Steps 3 to 6.
SEE FIG. 26
DISCONNECT THE POWER TO THE APPLIANCE.
1. Remove burner door and base plate.
2. Remove bracket.
3. Disconnect transformer.
4. Replace transformer.
5. Reconnect wiring.
6. Replace bracket.
SEE FIG. 27
DISCONNECT THE POWER TO THE APPLIANCE
1. Remove burner door and base plate.
.
2. Replace fuse.
ELECTRICAL COMPONENT
ACCESS
FIG. 25
DESN 511443
DESN 512577
DESN 512578
TRANSFORMER
FUSE
FIG. 26
FIG. 27