background image

5

       WARNING:   Rework  worksheet, add-
ing  the  space  of  the  adjoining
unconfined  space. The  combined  spaces
must  have  enough  fresh air to supply  all
appliances  in  both  spaces.

VENTILATION  AIR
Ventilation  Air  From  Inside Building
This  fresh  air  would  come  from  an  adjoining
unconfined  space.  When  ventilating   to  an
adjoining  unconfined space, you  must
provide  two permanent openings: one  within
12

"

 of  the  ceiling and  one  within  12

"

 of  the

floor  on  the wall  connecting  the  two  spaces
(see options 1 and 2,  Figure  2). You  can  also
remove  door  into  adjoining  room (see option
3, Figure 2). 

Follow  the  National Fuel  Gas

Code  NFPA 54/ANS Z223.1. Section  5.3,  Air
for  Combustion  and Ventilation

  for  required

size of  ventilation grills or ducts

If  the actual  Btu/Hr  used  is  less  than  the  maximum  Btu/Hr  the  space  can  support, the  space  is  an
unconfined  space. You  will  need  no  additional  fresh  air  ventilation.

 Example:
 Gas  water  heater          40,000        Btu/Hr
 Vent  free  heater    +      18,000        Btu/Hr
 Total                         =     58,000        Btu/Hr

3. Add the Btu/Hr of all fuel burning appliances in the space.
     Vent-free heater                                                       Btu/Hr
     Gas water heater*                                                         Btu/Hr
    Gas furnace                                                              Btu/Hr
     Vented gas heater                                                   Btu/Hr
     Gas Fireplace logs                                                   Btu/Hr
     Other gas appliances* +                                          Btu/Hr
    Total                                =                                        Btu/Hr
    *Do  not  include  direct-vent  gas  appliances. Direct-vent  draws  combustion  air  from  the  outdoors  and
       vents to the outdoors.

4. Compare  the  maximum  Btu/Hr  the  space  can  support  with  the  actual amount of Btu/Hr used.
                          Btu/Hr (maximum the space can support)
                         Btu/Hr (actual amount of Btu/Hr used)
         Example :  51,200 Btu/Hr(maximum the space can support)
                           58,000 Btu/Hr(actual amount of Btu/Hr used)
The  space  in  the  above  example  is  a  confined  space  because  the  actual  Btu/Hr  used  is  more  than  the
maximum  Btu/Hr  the  space  can  support.
You  must  provide  additional  fresh  air.  Your  options  are  as  follows:
A.  Rework  worksheet, adding  the  space  of  an  adjoining  room. If  the  extra  space  provides  an  unconfined
space, remove  door  to  adjoining  room  or  add  ventilation  grills   between  rooms. See

  Ventilation  Air  From

Inside  Building

, page 5.

B.  Vent  room  directly  to  the  outdoors. See  

Ventilation  Air  From  Outdoors

, page 6 .

C.  Install  a  lower  Btu/Hr  heater, if  lower  Btu/Hr  size  makes  room  unconfined.

Figure  2 -Ventilation  Air  from  Inside  Building

AIR  FOR  COMBUSTION  AND
VENTILATION

Continued

Содержание HR18MN-1

Страница 1: ...ller service agency or gas supplier Table of Contents ImportantSafetyInformation 2 Product Features 3 ProperVentilation FreshAir 4 Installation 6 OperatingYourHeater 10 Cleaning Maintenance 13 Trouble Shooting 14 Specifications 17 PartsList 19 WarrantyInformation 26 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal inj...

Страница 2: ...res heater s h o u l d b e k e p t o u t o f traffic and away from furniture and draperies Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shutting down Allow surface to cool before touching Carefully supervise young children when they are in the same room with heater M...

Страница 3: ...rce LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSZ223 1 also known as NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all pr...

Страница 4: ...ilation air by one of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as constructi...

Страница 5: ...in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the s...

Страница 6: ...ve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessories page 17 LOCATING HEATER This heater is designed to be mounted on a wall You can locate heater ...

Страница 7: ...e two holes are 16 inches apart from their c e n t e r s A t t a c h m o u n t i n g bracket to wall only in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls w...

Страница 8: ...ighten Note Do not replace lower front panel at this time Replace lower front panel after making gas connections and checking for leaks see pages 9 and 10 Figure 12 Installing Bottom Mounting Screws Attaching Mounting Bracket to Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mountin...

Страница 9: ...off valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer IMPORTANT Install an equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant ...

Страница 10: ... shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 for non thermostat models or p a g e 1 2 f o r t h e r m o s t a t models Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 11 for non ther...

Страница 11: ...ier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for thirty 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service person or gas supplier for repairs NOTE If pilot goes out repeat steps 3 through 7 Wait one 1 mi...

Страница 12: ...step 5 Turn control knob counterclock wise to the PILOT position Press in control knob for five 5 seconds see Figure 19 Note You may be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when released contact a qualified service person ...

Страница 13: ... the cabinet to remove dust MANUAL LIGHTING PROCEDURE 1 Remove lower front panel see Figure 7 page 7 2 Follow steps 1 through 5 under Lighting Instructions on page 12 3 With control knob pressed in strike match Hold match to pilot until pilot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Follow step 8 under Lighting Instructions on ...

Страница 14: ...ssed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Contro...

Страница 15: ...ocked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orifice 2 Replace burner orifice 3 Contact local natural gas company 1 Contact local natural ...

Страница 16: ...SSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve is defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at t...

Страница 17: ...vided with floor mounting stand Btu available Gas Type Ignition Pressure Regulator setting Inlet Gas Pressure inches of water Maximum Minimum Dimensions Inches HxWxD Heater Carton Weight pounds Heater Shipping HR18MN 6 000 12 000 18 000 Natural Only Piezo 6 W C 10 5 7 23 1 4 19 1 4 8 26 1 2 213 4 9 1 4 23 26 HR18TN 18 000 Natural Only Piezo 6 W C 10 5 7 23 1 4 19 1 4 8 26 1 2 213 4 9 1 4 24 27 HR3...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HR18MN ODS Pilot Assembly Burner Assembly ...

Страница 19: ...28001 ML070 03E ML071 01 ML072 01 PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control Valve Main Inlet Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Lin...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MOD ELS HR30MN ODS Pilot Assembly ...

Страница 21: ...RTS AVAILABEL NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control valve main inlet nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly C Burner Gas Line Assembl...

Страница 22: ...22 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR18TN ODS Pilot Assembly Burner Assembly ...

Страница 23: ...ML072 01 ML065 01 PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4 way connector 4 way connector Bracket 4 way connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping...

Страница 24: ...24 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR30TN ODS Pilot Assembly ...

Страница 25: ...T SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4 way Connector 4 way Connector Bracket 4 way Connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw ODS Gas Line Assembly C Burne...

Страница 26: ...26 ...

Страница 27: ......

Страница 28: ......

Отзывы: