background image

10

Figure 14 -Equipment  Shutoff  Valve

INSTALLATION

CHECKING GAS
CONNECTIONS

        

    WARNING:    Test  all  gas

piping   and  connections  for  leaks
after    installing    or    servicing.
Correct all  leaks   at   once.

          

 WARNING:   Never  use  an

open    flame    to   check   for    a
leak. Apply   a   mixture   of   liquid
soap  and   water    to   all   joints.
Bubbles  forming    show   a   leak.
Correct  all   leaks at  once.

Pressure  Testing  Gas  Supply
Piping  System
Test  Pressures  In  Excess  Of
1/2  PSIG  (3.5 K Pa)

1.   Disconnect   appliance   with   its
       appliance       main        gas     valve
     (control valve)   and   equipment
      shutoff    valve   from   gas   supply
     piping  system.  Pressures  in
       excess  of   1/2  psig  will  damage
      heater  regulator.
2.    Cap   off  open   end   of   gas  pipe

where  equipment  shutoff  valve

       was   connected.
3.     Pressurize             supply           piping

s y s t e m     b y     e i t h e r   u s i n g
compressed   air   or    opening
main gas valve  located  on  or

       near  gas  meter.
4.   Check  all  joints  of  gas  supply

piping  system.  Apply  mixture  of
liquid  soap  and  water  to  gas
joints. Bubbles  forming  show

      a  leak.
5.   Correct  all  leaks  at  once.
6.   Reconnect heater and equipment
       shutoff  valve  to  gas supply.  Check

reconnected   fittings  for  leaks.

Test  Pressures  Equal  To or
Less  Than  1/2  PSIG  (3.5 K Pa)

1.   Close equipment  shutoff  valve
      (see Figure 14).
2.   Pressurize  supply  piping  system
       by  either  using  compressed  air
    or opening  main gas valve
       located  on  or  near  gas  meter.
3.    Check  all  joints  from  gas  meter to
     equipment  shutoff  valve  (see
    Figure 15).  Apply mixture  of
     liquid  soap and  water  to  gas
     joints.  Bubbles  forming show
      a leak.
4.   Correct  all  leaks  at  once.

Pressure  Testing  Heater  Gas
Connections

1.  Open  equipment  shutoff  valve
      (see  Figure  14).
2.   Open   main  gas   valve   located
      on  or  near  gas  meter.
3.   Make    sure    control    knob    of
      heater  is  in  the  OFF position.
4.   Check  all  joints  from  equipment
      shutoff   valve   to   control   valve
      (see Figure 15 ).  Apply  mixture  of
        liquid   soap    and    water  to   gas
     joints. Bubbles  forming  show
      a  leak.
5.   Correct all leaks at once.
6.   Light    heater    (see   Operating

Heater,  pages  10  and  11  for
n o n - t h e r m o s t a t       m o d e l s   o r
p a g e   1 2   f o r     t h e r m o s t a t
models).  Check   the  rest  of  the

       internal  joints  for  leaks.
7.   Turn  off  heater (see  To  Turn  Off

Gas  to  Appliance,  page 11  for
non-thermostat  models  or  page
12 for  thermostat  models).

8.    Replace  lower  front  panel.

NON-THERMOSTAT MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

            WARNING:   If  you  do  not
f o l l o w       t h e s e       i n s t r u c t i o n s
exactly, a  fire  or  explosion  may
r e s u l t   i n   c a u s i n g       p r o p e r t y
damage,   personal   injury    or
loss  of  life.

A.  When  lighting  the  pilot,  follow
      these  instructions  exactly.
B.  BEFORE  LIGHTING  smell  all
     around   the  appliance  area  for
     gas.  Be  sure  to  smell  next  to
     the  floor  because  some  gas  is
     heavier  than  air  and  will  settle
      on the  floor .

WHAT TO DO IF YOU SMELL GAS

 

Do  not  try  to  light any  appliance.

 

Do not touch any electric switch;

       do not use any phone in your
       building.

 

Immediately       call      your     gas

    supplier from  a  neighbor’s
       phone.     Follow        the        gas
       supplier’s   instructions.

 

If     you     cannot    reach     your

    gas  supplier,  call   the  fire
      department.

C.  Use  only  your  hand  to  push  in
     or  turn  the   gas   control  knob.
     Never   use   tools.  If   the   knob
    will  not  push  in  or  turn  by
      hand, don’t  try  to  repair  it, call
     a qualified service technician or
      gas supplier. Force or attempted
    repair may result in  a fire or
      explosion.
D.  Do not use this appliance if any
      p a r t   h a s   b e e n   u n d e r   w a t e r .
    Immediately  call  a  qualified
     service  technician   to   inspect
      the  appliance   and   to   replace
      any  part  of  the  control  system
     and any gas control which has
      been  under  water.

Figure 15 -Checking  Gas  Joints

OPERATING YOUR HEATER

In the State of Massachusetts the gas
cock must be a T handle type. The State
of Massachusetts requires that a flex-
ible appliance connector cannot exceed
three feet in length.

Содержание HR18MN-1

Страница 1: ...ller service agency or gas supplier Table of Contents ImportantSafetyInformation 2 Product Features 3 ProperVentilation FreshAir 4 Installation 6 OperatingYourHeater 10 Cleaning Maintenance 13 Trouble Shooting 14 Specifications 17 PartsList 19 WarrantyInformation 26 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal inj...

Страница 2: ...res heater s h o u l d b e k e p t o u t o f traffic and away from furniture and draperies Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shutting down Allow surface to cool before touching Carefully supervise young children when they are in the same room with heater M...

Страница 3: ...rce LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSZ223 1 also known as NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all pr...

Страница 4: ...ilation air by one of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as constructi...

Страница 5: ...in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the s...

Страница 6: ...ve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessories page 17 LOCATING HEATER This heater is designed to be mounted on a wall You can locate heater ...

Страница 7: ...e two holes are 16 inches apart from their c e n t e r s A t t a c h m o u n t i n g bracket to wall only in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls w...

Страница 8: ...ighten Note Do not replace lower front panel at this time Replace lower front panel after making gas connections and checking for leaks see pages 9 and 10 Figure 12 Installing Bottom Mounting Screws Attaching Mounting Bracket to Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mountin...

Страница 9: ...off valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer IMPORTANT Install an equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant ...

Страница 10: ... shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 for non thermostat models or p a g e 1 2 f o r t h e r m o s t a t models Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 11 for non ther...

Страница 11: ...ier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for thirty 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service person or gas supplier for repairs NOTE If pilot goes out repeat steps 3 through 7 Wait one 1 mi...

Страница 12: ...step 5 Turn control knob counterclock wise to the PILOT position Press in control knob for five 5 seconds see Figure 19 Note You may be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when released contact a qualified service person ...

Страница 13: ... the cabinet to remove dust MANUAL LIGHTING PROCEDURE 1 Remove lower front panel see Figure 7 page 7 2 Follow steps 1 through 5 under Lighting Instructions on page 12 3 With control knob pressed in strike match Hold match to pilot until pilot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Follow step 8 under Lighting Instructions on ...

Страница 14: ...ssed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Contro...

Страница 15: ...ocked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orifice 2 Replace burner orifice 3 Contact local natural gas company 1 Contact local natural ...

Страница 16: ...SSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve is defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at t...

Страница 17: ...vided with floor mounting stand Btu available Gas Type Ignition Pressure Regulator setting Inlet Gas Pressure inches of water Maximum Minimum Dimensions Inches HxWxD Heater Carton Weight pounds Heater Shipping HR18MN 6 000 12 000 18 000 Natural Only Piezo 6 W C 10 5 7 23 1 4 19 1 4 8 26 1 2 213 4 9 1 4 23 26 HR18TN 18 000 Natural Only Piezo 6 W C 10 5 7 23 1 4 19 1 4 8 26 1 2 213 4 9 1 4 24 27 HR3...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HR18MN ODS Pilot Assembly Burner Assembly ...

Страница 19: ...28001 ML070 03E ML071 01 ML072 01 PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control Valve Main Inlet Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Lin...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MOD ELS HR30MN ODS Pilot Assembly ...

Страница 21: ...RTS AVAILABEL NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control valve main inlet nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly C Burner Gas Line Assembl...

Страница 22: ...22 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR18TN ODS Pilot Assembly Burner Assembly ...

Страница 23: ...ML072 01 ML065 01 PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4 way connector 4 way connector Bracket 4 way connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping...

Страница 24: ...24 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR30TN ODS Pilot Assembly ...

Страница 25: ...T SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4 way Connector 4 way Connector Bracket 4 way Connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw ODS Gas Line Assembly C Burne...

Страница 26: ...26 ...

Страница 27: ......

Страница 28: ......

Отзывы: