7
INSTALLATION
Figure 7 - Removing Lower Front
Panel Of Heater
Figure 4 -Mounting Clearances
As Viewed From Front Of Heater
Figure 5 - Moving Thermostat
Sensing Bulb
WARNING: Maintain the
minimum clearances shown
i n F i g u r e 4 . I f y o u c a n ,
provide greater clearances from
floor, ceiling, and joining wall.
INSTALLING THERMOSTAT
SENSING BULB
For T-Stat Models Only
1. Pull out the sensing bulb from the
two clips located in the shippng
position according to the direction
as shown by the arrow. There is no
need to take out the two bulb clips.
2. Take out the bulb clip from the
hardware package and insert it into
the square hole and then insert the
sensing bulb into the bulb clip (see
Figure 5).
FASTENING HEATER TO
WALL Mounting Bracket
The mounting bracket is located
on back panel of heater (see Figure6).
It has been taped there for shipping.
Remove mounting bracket from back
panel.
Removing Lower Front Panel Of
The Heater
1. Remove two Screws near bottom
corners of lower front panel
2. Pull bottom of lower front panel
forward, then down (see Figure 7).
Methods For Attaching
Mounting Bracket To Wall
Only use last hole on each end
of mounting bracket to attach
bracket to wall. These two holes
are 16 inches apart from their
c e n t e r s . A t t a c h m o u n t i n g
bracket to wall only in one of two
ways:
1. Attaching to wall stud
2. Attaching to wall anchor
Attaching to Wall Stud: This
method provides the strongest
hold. Insert mounting screws
through mounting bracket and
into wall studs.
Attaching to Wall Anchor: This
method allows you to attach
mounting bracket to hollow walls
(wall areas between studs) or to
solid walls (concrete or masonry).
Decide which method better suits
your needs. Either method will
provide a secure hold for the
mounting bracket.
Marking Screw Locations
1. Tape mounting bracket to wall
where heater will be located.
Make sure mounting bracket is
level.
2. Mark screw locations on
wall. (see Figure 8)
Note:
Only mark last hole on
each end of mounting bracket.
Insert mounting screws through
these holes only.
3. Remove tape and mounting
bracket from wall.
WARNING: Maintain
minimum clearances shown in
Figure 4. If you can, provide
greater clearances from floor
and joining wall.
IMPORTANT: Vent-free
heaters add moisture to the
air. Although this is beneficial,
installing heater in rooms
without enough ventilation air
may cause mildew to form
from too much moisture. See
Fresh Air for Combustion and
Ventilation
, pages 4 and 5.
Figure 8 - Mounting Bracket
Clearances
Figure 6 -Mounting Bracket
Location
Model HR30MN HR30TN
Model HR18MN HR18TN
Содержание HR18MN-1
Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HR18MN ODS Pilot Assembly Burner Assembly ...
Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MOD ELS HR30MN ODS Pilot Assembly ...
Страница 22: ...22 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR18TN ODS Pilot Assembly Burner Assembly ...
Страница 24: ...24 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR30TN ODS Pilot Assembly ...
Страница 26: ...26 ...
Страница 27: ......
Страница 28: ......