background image

25

PARTS  LIST

THERMOSTAT

MODELS

HR30TN

This  list  contains  replaceable  parts  for   your  heater.  When  ordering  replacenment parts,
following  the  instruction  listed under Replacement  Parts  on  page  17  of  this  manual.

KEY

NO.

1

2
3
4
5
6
7
8
9
10
11
12
13
14
14-1
14-2
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32

PART NO.

MB10002E

MB09001E
MB11001E
MB19001
SIT545-000
ML111-01
845-4.8x60Z
ML060-01
MB40007
ML096-01
ML115-01
ML116-01
ML073-01
ND1206x800x9
ND0803-8
ND0807-B2
ML026-01
ML069-02
MB40008
MB40009
MB40012
MB40013
MB40010
MB40014
MB40015
MB40011
ML090-01
ML056-01
MB40006
NRV81FI-6
96-4Z
ML079-01
MB29001E
ML083-03

MB28001
ML070-09E
ML071-01
ML072-01
ML065-01

PARTS  AVAILABLE  NOT  SHOWN

DESCRIPTION

Cabinet   Assembly

Lower  Front  Panel  Assembly
Reflector  Unit
Burner  Assembly
Thermostat  Valve Assembly
Thermostat  Valve Base
Self   Tapping  Screw
Mounting  Bracket
Thermostat  Outlet  Tube Assembly
4-way  Connector
4-way  Connector  Bracket
4-way  Connector  Fixed  Nut
Ignitor  Line
ODS  Pilot
Thermocouple
Ignitor  Electrode
ODS Mounting Bracket
Self  Tapping  Screw
ODS Gas Line Assembly
“C”  Burner  Gas   Line  Assembly
“C1”  Burner  Gas   Line  Assembly
“C2”  Burner  Gas   Line  Assembly
“B”  Burner  Gas   Line  Assembly
“B1”  Burner  Gas   Line  Assembly
“B2”  Burner  Gas   Line  Assembly
“A”  Burner  Gas   Line  Assembly
Injector
“T”  Joint
Main  Inlet  Tube  Assembly
Pressure  Regulator
Washer
Self  Locking  Screw
Grill  Guard
Ignitor  Assembly

Hardware  Assembly
CSA/AGA  Decal
Gas  Instruction  Decal
Inside   Warning  Label
Thermostat  Sensing  Bulb  Clip

QTY

1

1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1

14

1
1
1
1
1
1
1
1
5
2
1
1
2
2
1
1

1
1
1
1
2

Содержание HR18MN-1

Страница 1: ...ller service agency or gas supplier Table of Contents ImportantSafetyInformation 2 Product Features 3 ProperVentilation FreshAir 4 Installation 6 OperatingYourHeater 10 Cleaning Maintenance 13 Trouble Shooting 14 Specifications 17 PartsList 19 WarrantyInformation 26 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal inj...

Страница 2: ...res heater s h o u l d b e k e p t o u t o f traffic and away from furniture and draperies Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain hot for a time after shutting down Allow surface to cool before touching Carefully supervise young children when they are in the same room with heater M...

Страница 3: ...rce LOCAL CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas Code ANSZ223 1 also known as NFPA 54 Available from American National Standards Institute Inc 1430 Broadway New York NY 10018 National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 UNPACKING 1 Remove heater from carton 2 Remove all pr...

Страница 4: ...ilation air by one of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is defined as constructi...

Страница 5: ...in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors and vents to the outdoors 4 Compare the maximum Btu Hr the space can support with the actual amount of Btu Hr used Btu Hr maximum the s...

Страница 6: ...ve ground joint union test gauge connection sediment trap tee joint pipe wrench A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA design certified equipment shutoff valve from your dealer See Accessories page 17 LOCATING HEATER This heater is designed to be mounted on a wall You can locate heater ...

Страница 7: ...e two holes are 16 inches apart from their c e n t e r s A t t a c h m o u n t i n g bracket to wall only in one of two ways 1 Attaching to wall stud 2 Attaching to wall anchor Attaching to Wall Stud This method provides the strongest hold Insert mounting screws through mounting bracket and into wall studs Attaching to Wall Anchor This method allows you to attach mounting bracket to hollow walls w...

Страница 8: ...ighten Note Do not replace lower front panel at this time Replace lower front panel after making gas connections and checking for leaks see pages 9 and 10 Figure 12 Installing Bottom Mounting Screws Attaching Mounting Bracket to Wall Note Wall anchors mounting screws and spacers are in hardware package The hardware package is provided with heater Attaching to Wall Stud Method For attaching mountin...

Страница 9: ...off valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the CSA AGA design certified equipment shutoff valve from your dealer IMPORTANT Install an equipment shutoff valve in an accessible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant ...

Страница 10: ... shutoff valve to control valve see Figure 15 Apply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks at once 6 Light heater see Operating Heater pages 10 and 11 for non thermostat models or p a g e 1 2 f o r t h e r m o s t a t models Check the rest of the internal joints for leaks 7 Turn off heater see To Turn Off Gas to Appliance page 11 for non ther...

Страница 11: ...ier for repairs Until repairs are made light pilot with match To light pilot with match see Manual Lighting Procedure 7 Keep control knob pressed in for thirty 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop up when released contact a qualified service person or gas supplier for repairs NOTE If pilot goes out repeat steps 3 through 7 Wait one 1 mi...

Страница 12: ...step 5 Turn control knob counterclock wise to the PILOT position Press in control knob for five 5 seconds see Figure 19 Note You may be running this heater for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds This will allow air to bleed from the gas system If control knob does not pop up when released contact a qualified service person ...

Страница 13: ... the cabinet to remove dust MANUAL LIGHTING PROCEDURE 1 Remove lower front panel see Figure 7 page 7 2 Follow steps 1 through 5 under Lighting Instructions on page 12 3 With control knob pressed in strike match Hold match to pilot until pilot lights 4 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Follow step 8 under Lighting Instructions on ...

Страница 14: ...ssed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve not fully open 4 Thermocouple connection loose at control valve 5 Pilot flame is not touching thermocouple which allows thermocouple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 6 Thermocouple damaged 7 Contro...

Страница 15: ...ocked positions 1 Residues from manufacturing processes 1 Metal is expanding while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Maintenance Page 13 or replace burner orifice 2 Replace burner orifice 3 Contact local natural gas company 1 Contact local natural ...

Страница 16: ...SSIBLE CAUSE 1 Heater burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement at top of page 2 Control valve is defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning Statement at t...

Страница 17: ...vided with floor mounting stand Btu available Gas Type Ignition Pressure Regulator setting Inlet Gas Pressure inches of water Maximum Minimum Dimensions Inches HxWxD Heater Carton Weight pounds Heater Shipping HR18MN 6 000 12 000 18 000 Natural Only Piezo 6 W C 10 5 7 23 1 4 19 1 4 8 26 1 2 213 4 9 1 4 23 26 HR18TN 18 000 Natural Only Piezo 6 W C 10 5 7 23 1 4 19 1 4 8 26 1 2 213 4 9 1 4 24 27 HR3...

Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HR18MN ODS Pilot Assembly Burner Assembly ...

Страница 19: ...28001 ML070 03E ML071 01 ML072 01 PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control Valve Main Inlet Nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Lin...

Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MOD ELS HR30MN ODS Pilot Assembly ...

Страница 21: ...RTS AVAILABEL NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly ODS Pilot Assembly Thermocouple lgnitor Electrode ODS Mounting Bracket Self Tapping Screw Control Valve Ignitor Line Control Valve Bracket Control Valve Fixed Nut Control valve main inlet nut Main Inlet Tube Assembly ODS Gas Line Assembly Burner Gas Line Assembly C Burner Gas Line Assembl...

Страница 22: ...22 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR18TN ODS Pilot Assembly Burner Assembly ...

Страница 23: ...ML072 01 ML065 01 PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4 way connector 4 way connector Bracket 4 way connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping...

Страница 24: ...24 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR30TN ODS Pilot Assembly ...

Страница 25: ...T SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Burner Assembly Thermostat Valve Assembly Thermostat Valve Base Self Tapping Screw Mounting Bracket Thermostat Outlet Tube Assembly 4 way Connector 4 way Connector Bracket 4 way Connector Fixed Nut Ignitor Line ODS Pilot Thermocouple Ignitor Electrode ODS Mounting Bracket Self Tapping Screw ODS Gas Line Assembly C Burne...

Страница 26: ...26 ...

Страница 27: ......

Страница 28: ......

Отзывы: