11
Figure 17 - Pilot
OPERATING YOUR HEATER
LIGHTING
INSTRUCTIONS
1 . S TO P ! R e a d t h e s a f e t y
information on the side of
heater.
2. Check that gas supply to
heater is on.
3. Push in gas control knob
slightly and turn clockwise
to the OFF position.
NOTE
: Knob cannot be turned from
“PILOT” to “OFF” unless knob is
p u s h e d i n s l i g h t l y . D o n o t
force.
4. Wait five (5) minutes to clear
out any air. Then smell for
gas, including near the floor.
If you smell gas, STOP!
Follow “B” in the safety
information on the side of the
heater. If you do not smell
gas, go to the next step.
5. Push in gas control knob
slightly and turn
counterclockwise
to
“PILOT/IGN” and depress for
five(5) seconds
NOTE
: The first time that the
h e a t e r i s o p e r a t e d a f t e r
connecting the gas supply , the
control knob should be depressed
for about thirty (30) seconds. This
will allow air to bleed from the gas
system.
6. With control knob pressed in,
push down and release the
ignitor button. This will light
pilot. If needed, keep pressing
ignitor button until pilot lights.
NOTE
: If pilot does not stay lit,
refer to
Troubleshooting
, pages
14 through 16. Also contact a
qualified service person or gas
supplier for repairs. Until repairs
are made, light pilot with match.
To light pilot with match, see
Manual Lighting Procedure.
7. Keep control knob pressed in
for thirty (30) seconds after
lighting pilot. After 30
seconds, release control knob.
If control knob does not pop
up when released, contact a
qualified service person or
gas supplier for repairs.
NOTE
: If pilot goes out, repeat
steps 3 through 7. Wait one (1)
minute before lighting pilot again
8. Turn control knob
counterclockwise
to
desired heating level. The
main burner should light. Set
control knob to any heat level
between HI and LO.
TO TURN OFF
GAS TO APPLIANCE
Shutting Off Heater
1. Turn control knob clockwise
to the OFF position.
2. Turn off all electric power to
the appliance if service is to
be performed.
SHUTTING OFF BURNER ONLY
(PILOT STAYS LIT)
Turn control knob clockwise
to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
1. Remove lower front panel (see
Figure 7 page 7).
2. Follow steps 1 through 5
under
Lighting Instructions
.
3. With control knob pressed in,
strike match. Hold match to
pilot until pilot lights.
4. Keep control knob pressed in
for 30 seconds after lighting
pilot. After 30 seconds, release
control knob. Follow step 8
under
Lighting Instructions
.
5. Replace lower front panel.
Figure 16 - Control Knob In The OFF
Position
Figure 18 - Burner Patterns
Manual Control Models
Содержание HR18MN-1
Страница 18: ...18 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MODELS HR18MN ODS Pilot Assembly Burner Assembly ...
Страница 20: ...20 ILLUSTRATED PARTS BREAKDOWN NON THERMOSTAT MOD ELS HR30MN ODS Pilot Assembly ...
Страница 22: ...22 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR18TN ODS Pilot Assembly Burner Assembly ...
Страница 24: ...24 ILLUSTRATED PARTS BREAKDOWN THERMOSTAT MODELS HR30TN ODS Pilot Assembly ...
Страница 26: ...26 ...
Страница 27: ......
Страница 28: ......