7 Cleaning and servicing the heating system – Procedure
56
E
MERGENCY
FILLING
OF
THE
RESERVOIR
15.
Close the reservoir and the boiler in the reverse order.
✓
The reservoir and the flap of the delivery unit have been cleaned.
C
LEANING
THE
PELLET
STORAGE
ROOM
HDG
AUGER
HDG
SUCTION
SYSTEM
WITH
SUCTION
PROBES
G
ENERAL
INFORMATION
1.
Switch the heating system off.
✎
See the “HDG Control” operating manual, chapter “5 Using the
control unit”, section “5.3 Switching off the heating system”.
2.
Allow the fire in the heating system to burn out and cool down.
3.
Open the access hatch of the pellet storage room.
4.
Remove the wooden boards inside the access hatch.
12.
Mount the inspection hatch
(2) as touch protection on the
opening for the conveyor
auger.
13.
If necessary, fasten the pellet
scuttle (1) to the reservoir.
14.
Fill the pellets into the
reservoir (using the pellet
scuttle (1) if necessary).
Figure 7/23 - Emergency filling
1
2
Caution!
Danger of injury from the rotating auger!
When the heating system is turned on, the auger rotates in the
pellet storage room. Hands and feet could thereby be crushed.
Switch the heating system off before you enter the pellet storage
room.
Caution!
Material compression at the suction probes
If the pellet storage room is entered, there can be material
compression in the suction probes. This can lead to the pellet
delivery being impaired.
When you enter the pellet storage room, be sure not to stand on the
pellets in the area of the suction sensors.