![HDG K10 Скачать руководство пользователя страница 53](http://html.mh-extra.com/html/hdg/k10/k10_operating-manual_2112440053.webp)
7 Cleaning and servicing the heating system – Procedure
53
✓
The flue gas fan and the cleaning shaft are now clean.
C
LEANING
THE
FLUE
GAS
PIPE
1.
Switch the heating system off.
✎
See the “HDG Control” operating manual, chapter “5 Using the
control unit”, section “5.3 Switching off the heating system”.
2.
Allow the fire in the heating system to burn out and cool down.
7.
Screw the inspection hatch (2) securely onto the flue gas pipe (3)
with the wing nut (1).
✓
The cleaning of the flue gas pipe is completed.
C
HECK
THE
FILL
LEVEL
OF
THE
WATER
TANK
7.
Clean the cleaning shaft lid (1)
using a scraper.
8.
Remove the flue ash in the
cleaning shaft (1) with a
vacuum cleaner.
9.
Close the boiler in the reverse
order.
Figure 7/16 - Cleaning the cleaning shaft
1
Important!
Observe the “Generally applicable safety instructions” in this
section.
3.
Unscrew the wing nut (1) on
the inspection hatch lid (2).
4.
Remove the inspection hatch
lid (2) from the flue gas pipe
(3).
5.
Check whether the flue gas
pipe (3) needs cleaning.
6.
If necessary, suction the ash
out of the flue gas pipe using
a vacuum cleaner (3).
Figure 7/17 - Clean the flue gas pipe
1
2
3
Important!
Observe the “Generally applicable safety instructions” in this
section.