background image

INSTALLER: PLEASE LEAVE THIS MANUAL WITH
THE OWNER!!

NOTE:  This  heater  should  not  be  installed  in  a  bedroom  or
bathroom.

SAFETY NOTICE

<

CAUTION: HOT WHILE IN OPERATION. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY
CAUSE SKIN BURNS.

<

IF THIS HEATER IS NOT PROPERLY INSTALLED,
A HOUSE FIRE MAY RESULT.

<

CONTACT LOCAL BUILDING OFFICIALS ABOUT RE-
STRICTIONS AND INSTALLATION INSPECTION REQUIRE-
MENTS IN YOUR AREA.

<

FAILURE TO COMPLY WITH OWNERS' MANUAL IN-
STRUCTIONS WILL VOID YOUR WARRANTY!

Please read this entire manual before installation. Save these instructions.

EF4001C AutoLite Pellet Stove Insert

Installation & Operating Instructions

PLEASE  READ  THIS  ENTIRE  MANUAL  BEFORE  INSTALLATION
AND  USE  OF  THIS  PELLET  FUEL-BURNING  ROOM  HEATER.
FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN
PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.

GENERAL INFORMATION

Installation and repair should be done by a qualified

service person. The heater should be inspected before use
and at least annually by a professional service person. More
frequent cleaning may be required due to fuel quality,
excessive lint from carpeting, bedding material, etc. It is
imperative that control compartments, burn pot and circulat-
ing air passageways of the heater be kept clean.

The EASYFIRE Pellet heater has been designed and
approved for burning 

PREMIUM WOOD PELLETS OF

HIGHEST BTU OUTPUT AND LOWEST % OF ASH
CONTENT ONLY. 

Burning biomass fuels in other forms or

poor quality pellet fuel is not permitted and will void
your warranty and/or could cause a burn back or
house fire. 

FOR BEST RESULTS THE WOOD PELLET

FUEL SHOULD BE ¼” DIAMETER AND
APPROXIMATELY 1”. 

Burning other forms of fuel  is not

permitted and will void all warranties.

This unit has been approved for use with a

 Ø 3" Type L

Pellet Vent System or Stainless Chimney Liner

 (Ø 4" on

runs 10 feet and above).

NEVER use gasoline, gasoline-type lantern fuels,

kerosene, charcoal lighter fluid, or similar liquids to start or
"freshen up" a fire.  Keep all such liquids well away from the
heater while it is in use.

Ashes must be disposed of in a metal container with a

tight fitting lid and placed on a noncombustible floor or
ground, well away from all fuels, pending final disposal.

NOTE :

  During the first few burns the high temperature

paint and sealant used in manufacture will emit some odor
and smoke. Open doors and windows to the outside for
proper ventilation during the first burn cycle and curing of
the paint.

This heater, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the 

National Electrical Code, ANSI/NFPA 70-

2013

.

Provide adequate clearances around air openings into the

combustion chamber and adequate accessibility clearance for
servicing  and  proper  operation.  Never  obstruct  the  front
opening of the heater.

Sierra Products, Inc.
63 Laxalt Dr.
Carson City, NV 89706
(775) 241-2586

Содержание EasyFire EF4001C

Страница 1: ...LETS OF HIGHEST BTU OUTPUT AND LOWEST OF ASH CONTENT ONLY Burning biomass fuels in other forms or poor quality pellet fuel is not permitted and will void your warranty and or could cause a burn back or house fire FOR BEST RESULTS THE WOOD PELLET FUEL SHOULD BE DIAMETER AND APPROXIMATELY 1 Burning other forms of fuel is not permitted and will void all warranties This unit has been approved for use ...

Страница 2: ...N OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTIONS Check with local building officials for specific code requirements A listed type L Pellet Vent Pipe or Stainless Liner is MANDATORY on all installations WARNING Installation of a Mobile Attachment Home Kit P N 10412 and outside combustion air is mandatory in mobile or modular home ins...

Страница 3: ...IF NOT FULLY SUPPORTED IT COULD FALL FORWARD 4 Install vent system into existing chimney by using 3 flex from left side of hearth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install Ø4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and combustion air duct Install a flashing cover over chi...

Страница 4: ...he installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of cou...

Страница 5: ... then 12 gauge wire must be used Check with your local electrical professional to make sure you have used the proper gauge wire cable a Unplug heater from wall outlet and 12VDC power b Mount millivolt style remote receiver box to rear of stove using double sided tape b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 d Reconnect AC power and follow instructions with remo...

Страница 6: ...placed on a noncombustible floor or ground well away from all fuels pending final disposal This heater when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 2006 Provide adequate clearances around air openings into the combustion chamber and adequateaccessibilityclearance for servicing and proper ...

Страница 7: ... the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIRE will be feeding approximately three 3 pounds of pellets per hour and the flame will fluctuate between 3 and 8 of fire D In the HIGH position the EASYFIRE will be feeding approximately 4 lbs per...

Страница 8: ...again This will give you another 10 minutes to get the pellets lit The reason for the timer function is so that the heater will automatically shut down if the fire goes out Pellets do not feed in the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIR...

Страница 9: ...ding on hopper height Open the top lid and fill the hopper with pellets Figure 9 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a clean effi cient burn Poor quality pellets will burn rich with black soot and ash will accumulate quickly Qualitypellets will burn clean and as...

Страница 10: ...NG Risk of electrical shock disconnect all power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIRE Pellet Heater requires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly ash Some ash will accumulate in the heat exchan...

Страница 11: ...nd a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is COOL 7 Door glass replacement Should the door glass become broken it may be replaced by scraping the sealer from around the outer edge of the glass Carefully pry glass from door frame then clean all sealer from frame Ob...

Страница 12: ...an and or clean your pipe and heater thoroughly If you feel the Fly ash build up is excessive we suggest that you try another brand In moist climates the pellets and Fly ash can actually absorb moisture from the air and create creosote and a severe clogging problem Keep this in mind when you store and handle your pellets The heater warranty does not cover the quality of the fuels used or the way t...

Страница 13: ...BLY 6 120114 CONTROL BOARD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR RELAY 13 120118 PUSH BUTTON SWITCH V2 1 14 110058 HANDLE ASSEMBLY 15 10407 SURROUND ASSEMBLY 63 Laxalt Dr Carson City NV 89706 Phone 1 775 241 2586 Fax 1 ...

Страница 14: ...www sierraproductsinc com P N 140706r7 02 21 ...

Отзывы: