Figure 9
Figure 10 Air Wash Box Placement
based on the EasyFire digital control system requirements.
If the house AC power should quit, the AutoLite system will
not be available however, with the optional battery attached
the stove can be manually lit and operate on battery power
for several days (depending on battery size, refer to the
EasyFire installation manual).
The most effective installation of the EasyFire AutoLite
Stove is to connect the unit to a thermostat. This can be
accomplished using a standard wall thermostat or a remote
control thermostat. A remote control thermostat can be
purchased from your local dealer and installed in a few
minutes. This will allow the stove to start and shut down
when there is a call for heat.
If your house power is out the AutoLite system will not be
able to start the stove when the thermostat calls for heat.
However if the stove is operating when the power goes out
the stove will not shut down operating on the backup
battery. Your EasyFire will turn down to low when the
thermostat calls for shut down and then turn up to the
setting on the control panel when the thermostat calls for
heat. A true back up heat source!
GENERAL WARNINGS
The EASYFIRE Pellet Stove and Insert has been
designed and approved for burning
wood pellet fuel only
.
Burning solid fuel in other forms is not permitted and will
void all warranties.
NEVER use gasoline, gasoline-type lantern fuels,
kerosene, charcoal lighter fluid, or similar liquids to start or
"freshen up" a fire. Keep all such liquids well away from the
heater while it is in use.
Ashes must be disposed of in a metal container with a
tight fitting lid and placed on a noncombustible floor or
ground, well away from all fuels, pending final disposal.
This heater, when installed, must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the
National Electrical Code, ANSI/NFPA 70-
2006
.
Provide adequate clearances around air openings into the
combustion chamber and adequate accessibility clearance for
servicing and proper operation. Never obstruct the front
opening of the heater.
The pellet heater must be operated with a power source
and will not operate using natural draft. If there is a power
failure the heater will shut down. If the 12 volt back-up system
is installed, the heater will automatically switch to 12 volt
power. An
optional
backup battery is available for the unit
which lasts approximately 48 hrs on high and 72 hrs on low.
A bigger battery may be purchased if desired for longer
durations.
The EasyFire Pellet Heater has been listed by PFS, Inc. to
ASTM, U.L.,and EPA Standards.
FUEL SELECTION
Proper fuel selection is important for overall operation. Your
stove operates best with 1/4" diameter wood pellets that are
no longer than 3/4" long. The pellets should be specifically
manufactured for use pellet heaters. Use of fuel non-
conforming fuel will cause the stove to operate erratically.
Additionally, a low ash content of below 1% is required and
will reduce your cleaning and maintenance time. Store pellets
in a clean dry area. Do not use pellets that have been damp
or have a moisture level above 5%.
The quality of pellet fuel varies from brand to brand. This will
affect the efficiency of your heater. We suggest that you try
several brands until you find one that gives you a clean effi-
cient burn. Poor quality pellets will burn rich with black soot
and ash will accumulate quickly. Quality pellets will burn clean
and ash build up will be minimal.