Sierra Products EasyFire EF4001C Скачать руководство пользователя страница 4

Figure 6

 

Connection Panel Lower Right Side

Autolite Wiring Diagram

and  rear  of  unit  and  raising  the  top  by  1"  increments  until
desired height and reinstalling screws 

(Figure 4)

.

7.

Slide insert into fireplace and center. Level as required,
then secure vent to outlet on left side of insert. Connect
combustion air duct and secure.

Note - For best insert operation the flexible vent
installation should not have any tight bends. Try to
achieve a smooth sweep to the vertical rise.

SURROUND INSTALLATION

The surround supplied with the insert is adjustable in

height so as to allow for many installation perimeters.

1.

After the insert is in position, install left and right surround
sides by attaching them to the two side brackets using the
four  1/4-20  bolts  provided.  The  retainer  nuts  on  the
surround sides may be installed at any vertical position to
accommodate the installation.

2.

Slide the surround top panel between the hopper top and
cover. Push the panel down until the screw holes align
with the side legs. Install the (4) #8 screws provided.
Install power cord into the receptacle on the right side of

the insert. Route cord behind surround leg and out to a
ground plus.

AUTOLITE INSTALLATION INSTRUCTIONS

  The AutoLite System is factory installed with the only
installation requirements being the optional thermostat.

Wall Thermostat Installation:

  The wall thermostat is designed to automatically regulate
the room temperature from the control panel heat setting to
the “Off” setting based upon room temperature. Remember
to leave the control panel on the "Medium or High" position
when utilizing the wall thermostat feature.

  The following is a step by step procedure for installing the
optional wall thermostat. Note connection terminals on left
side of unit at rear (

Figure 7

). Use 18/2 thermostat wire for

the installation.

a.

Unplug heater from wall outlet and 12VDC power!

b.

Remove factory jump wire and hook up thermostat
wires to terminals (

Figure 7

).

c.

Locate thermostat approximately 10 to 12 feet from
heater or in area that requires steady temperature.

d.

Run thermostat wires from heater to thermostat along
wall or under carpet etc. and hook wires to
thermostat terminals.  On new construction you can,
of course, run wire in the walls before sheet rock or
paneling is done.

e.

Reconnect AC power.

f.

Make sure all wiring is completed before plugging the
EASYFIRE Heater back into the wall outlet.

IMPORTANT

 - Any electrical work performed on the

EASYFIRE Heater should  be done by qualified personnel.

Optional Remote Control Thermostat Installation:

  The remote thermostat is designed to automatically
regulate the room temperature from the control panel heat
setting to the “Off” setting based upon room temperature
and placement of the remote thermostat. Remember to
leave the control panel on the "Medium or High" position
when utilizing the wall thermostat feature.

  The following is a step by step procedure for installing the
optional remote thermostat. Note connection terminals on
rear of unit (

Figure 7

).

a.

Unplug heater from wall outlet and 12VDC power!

b.

Mount millivolt style remote receiver box to rear of
stove using double-sided tape.

b.

Remove factory jump wire and hook up thermostat
wires to terminals (

Figure 7

).

d.

Reconnect AC power and follow instructions with
remote thermostat regarding set up.

IMPORTANT

 - Any electrical work performed on the

 EASYFIRE Heater should  be done by qualified personnel.

DOOR HANDLE ASSEMBLY

The door handle and latch must be assembled and
adjusted prior to the operation of the stove.

1. Position handle assembly through door and secure with

collar by sliding over shaft and tightening with allen
wrench provided.

2. Position latch on end of shaft with flat facing allen screw.

Depending on gasket, shaft will protrude approx. 1/4"
through back of latch collar. Snug allen screw.

4

Содержание EasyFire EF4001C

Страница 1: ...LETS OF HIGHEST BTU OUTPUT AND LOWEST OF ASH CONTENT ONLY Burning biomass fuels in other forms or poor quality pellet fuel is not permitted and will void your warranty and or could cause a burn back or house fire FOR BEST RESULTS THE WOOD PELLET FUEL SHOULD BE DIAMETER AND APPROXIMATELY 1 Burning other forms of fuel is not permitted and will void all warranties This unit has been approved for use ...

Страница 2: ...N OUTSIDE AIR INSTALLATION CAUTION DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM INSTALLATION INSTRUCTIONS Check with local building officials for specific code requirements A listed type L Pellet Vent Pipe or Stainless Liner is MANDATORY on all installations WARNING Installation of a Mobile Attachment Home Kit P N 10412 and outside combustion air is mandatory in mobile or modular home ins...

Страница 3: ...IF NOT FULLY SUPPORTED IT COULD FALL FORWARD 4 Install vent system into existing chimney by using 3 flex from left side of hearth passing damper and continuing to the top of the chimney If the total vent length is longer than 10 Feet install Ø4 vent from that point to top of chimney Figure 6 5 Pack fiberglass insulation around the vent pipe and combustion air duct Install a flashing cover over chi...

Страница 4: ...he installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 c Locate thermostat approximately 10 to 12 feet from heater or in area that requires steady temperature d Run thermostat wires from heater to thermostat along wall or under carpet etc and hook wires to thermostat terminals On new construction you can of cou...

Страница 5: ... then 12 gauge wire must be used Check with your local electrical professional to make sure you have used the proper gauge wire cable a Unplug heater from wall outlet and 12VDC power b Mount millivolt style remote receiver box to rear of stove using double sided tape b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 d Reconnect AC power and follow instructions with remo...

Страница 6: ...placed on a noncombustible floor or ground well away from all fuels pending final disposal This heater when installed must be electrically grounded in accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 2006 Provide adequate clearances around air openings into the combustion chamber and adequateaccessibilityclearance for servicing and proper ...

Страница 7: ... the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIRE will be feeding approximately three 3 pounds of pellets per hour and the flame will fluctuate between 3 and 8 of fire D In the HIGH position the EASYFIRE will be feeding approximately 4 lbs per...

Страница 8: ...again This will give you another 10 minutes to get the pellets lit The reason for the timer function is so that the heater will automatically shut down if the fire goes out Pellets do not feed in the FAN position B In the LOW position the EASYFIRE will be feeding approximately 1 to 1 lbs of pellets per hour and the flame will fluctuate between 1 and 6 in height C In the MEDIUM position the EASYFIR...

Страница 9: ...ding on hopper height Open the top lid and fill the hopper with pellets Figure 9 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a clean effi cient burn Poor quality pellets will burn rich with black soot and ash will accumulate quickly Qualitypellets will burn clean and as...

Страница 10: ...NG Risk of electrical shock disconnect all power before servicing ALWAYS TURN YOUR Heater OFF LET IT COOL BEFORE CLEANING Your EASYFIRE Pellet Heater requires routine maintenance for maximum performance and is mandatory for the warranty to remain in effect The following procedures should be studied carefully and performed regularly as indicated 1 Fly ash Some ash will accumulate in the heat exchan...

Страница 11: ...nd a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is COOL 7 Door glass replacement Should the door glass become broken it may be replaced by scraping the sealer from around the outer edge of the glass Carefully pry glass from door frame then clean all sealer from frame Ob...

Страница 12: ...an and or clean your pipe and heater thoroughly If you feel the Fly ash build up is excessive we suggest that you try another brand In moist climates the pellets and Fly ash can actually absorb moisture from the air and create creosote and a severe clogging problem Keep this in mind when you store and handle your pellets The heater warranty does not cover the quality of the fuels used or the way t...

Страница 13: ...BLY 6 120114 CONTROL BOARD V2 1 6A 110080 MAIN FUSE 1 AMP 6B 110510 AUTOLITE FUSE 5 AMP 7 200549 HEAT EXCHANGE COVER 8 110456 ASH DRAWER FIBER ROPE GASKET 9 110451 ASH DRAWER KNOB 10 120117 IGNITOR 200W 11 300512 BURN POT AL V2 12 120120 IGNITOR RELAY 13 120118 PUSH BUTTON SWITCH V2 1 14 110058 HANDLE ASSEMBLY 15 10407 SURROUND ASSEMBLY 63 Laxalt Dr Carson City NV 89706 Phone 1 775 241 2586 Fax 1 ...

Страница 14: ...www sierraproductsinc com P N 140706r7 02 21 ...