USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

1-888-HAY-INDL (1-888-429-4635) 

ISHCP3000FC Rev A 11/30/16

 

Pg. 12 of 16

 

www.haywardflowcontrol.com 

Hayward Flow Control 

Shaft Seal Change Instructions 

 

IMPORTANT SAFETY INSTRUCTIONS 

PLEASE READ AND FOLLOW ALL INSTRUCTIONS

 

 

When servicing electrical equipment, basic safety precautions should always be observed including the following.  Failure to follow 
instructions may result in injury. 
 

 

WARNING

 

– 

To reduce risk of injury, do not permit children to use this product. 

 

 

Disconnect all electrical power service to pump before beginning shaft seal replacement. 

 

Only qualified personnel should attempt rotary seal replacement.  Contact Hayward Flow Control if you have any questions. 

 

See “Parts Diagram” for pump component locations. 

 

Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal.  Foreign 
matter or improper handling will damage the sealing surfaces. 

 

Removing the Motor Assembly  

(See Parts Diagram on page 14 of this manual for pump component locations.)

 

 

 

 

1.

 

Remove the six (6) 5/16" x 2" hex head bolts

 

(item #20), which hold the motor assembly to the pump/strainer 

housing (item #9), using a 1/2" wrench or socket. 

2.

 

Slide the motor assembly out of the pump/strainer housing (item #9), exposing the diffuser (item #12).  Remove the 
four (4) diffuser screws (item #11), and pull the diffuser (item #12) off of the seal plate (item #18) to expose the 
impeller (item #15). 

Removing the Impeller  

(See Parts Diagram on page 14 of this manual for pump component locations.)

 

 

3.

 

To prevent motor shaft from turning, 

insert a 5/16” allen wrench into the end of the motor shaft through the center 

hole in the motor end cover/canopy.  

4.

 

Rotate the impeller (item #15) counterclockwise and remove.  The spring portion of the seal assembly (item #16) is 
now exposed.  Note carefully the position of the spring seal, and remove it.  NOTE - Replace motor cover to protect 
delicate motor parts.                                                                                         

                                                                                         

 

Removing the Seat  

(See Parts Diagram on page 14 of this manual for pump component locations.)

 

 

5.

 

Remove the seal plate (item #18) from the motor by removing the four (4) 3/8” x 1” hex head bolts (item #21) that 
secure it to the motor, using a 1/2” wrench or socket.   

6.

 

Press the ceramic seat with rubber cup out of the seal plate (item #18).  If tight, use a small screwdriver to tap seal 
out. 

STOP

 - Clean all recesses & parts to be reassembled.  Inspect gaskets & replace if necessary. 

 

 

Содержание LifeStar MV Series

Страница 1: ...and or death This is the safety alert symbol When you see this symbol on your equipment or in this manual look for one of the following signal words and be alert to the potential for personal injury...

Страница 2: ...event excess mechanical loading on Hayward products due to system misalignment weight shock vibration and the effects of thermal expansion and contraction 6 The effect of temperature on plastic piping...

Страница 3: ...ectrical Electrical Specs Voltage Grounding and Bonding Wiring Startup Operation Prior to Start Up Starting Priming the Pump Maintenance Storage Winterization Storing Pump For Winterization Shaft Seal...

Страница 4: ...utlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material...

Страница 5: ...codes for bonding requirements WARNING Risk of Electric Shock Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verif...

Страница 6: ...to reduce friction loss Pump height locations should be as close to system level as possible and NOT to exceed 8 feet Suction lines should have continuous slope upward from lowest point in line Joint...

Страница 7: ...fittings but at least two suction outlets Avoid f entrapping suction fitting in All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electric Code...

Страница 8: ...may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding and Bo...

Страница 9: ...t be sure to add their amp loads before calculating wire and circuit breaker sizes Use the load circuit breaker as the Master On Off switch WARNING Risk of dangerous or fatal electrical shock Be sure...

Страница 10: ...close filter manual air relief valve when a steady stream of water not air or air and water is discharged from valve Failure to do so could result in severe personal injury CAUTION NEVER OPERATE THE P...

Страница 11: ...CAUTION Allowing the pump to freeze will void the warranty CAUTION Use ONLY propylene glycol as antifreeze in your system Propylene glycol is non toxic and will not damage plastic system components ot...

Страница 12: ...lts item 20 which hold the motor assembly to the pump strainer housing item 9 using a 1 2 wrench or socket 2 Slide the motor assembly out of the pump strainer housing item 9 exposing the diffuser item...

Страница 13: ...d surface facing toward the polished surface of the ceramic seat Replacing the Impeller and Diffuser See Parts Diagram on page 14 of this manual for pump component locations 11 Screw the impeller item...

Страница 14: ...er Housing Flange O Ring 1 9 HCXP3000A Pump Housing with Drain Plug 1 10 HCXP338V60 Diffuser O Ring 1 11 SPX2700Z3SSPAK4 Diffuser Screws 4 Pack 1 12 HCXP3000B Diffuser 2 5 HP 1 12 HCXP3000B2 Diffuser...

Страница 15: ...a qualified professional if the voltage is more than 10 lower than the motor nameplate voltage rating 2 Impeller jammed with debris Have a qualified repair professional open the pump and remove the de...

Страница 16: ...uding a new seal assembly Noisy Pump 1 Air leak in suction piping cavitation caused by restricted or undersized suction line or leak at any joint low water level in system and unrestricted discharge r...

Отзывы: