USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

 

 

1-888-HAY-INDL (1-888-429-4635) 

ISHCP3000FC Rev A 11/30/16

 

Pg. 5 of 16

 

www.haywardflowcontrol.com 

Hayward Flow Control 

 

 

WARNING

 

– To reduce the risk of electric shock replace damaged wiring immediately.   

 

WARNING

 

– 

Ground all electrical equipment before connecting to electrical power supply.  Failure to ground all electrical 

equipment can cause serious or fatal electrical shock hazard.

 

 

WARNING

 –

 

Do NOT ground to a gas supply line.

 

 

WARNING

 

– To avoid dangerous or fatal electrical shock, turn OFF power to all electrical equipment before working on 

electrical connections. 

 

WARNING 

– Failure to bond all electrical equipment to system structure will increase risk for electrocution and could result in 

injury or death.  To reduce the risk of electric shock, see installation instructions and consult a professional electrician on how to bond all 
electrical equipment.  Also, contact a licensed electrician for information on local electrical codes for bonding requirements. 

 

WARNING 

– Risk of Electric Shock.  Connect only to a branch circuit protected by a ground-fault circuit-interrupter (GFCI).  

Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI. 

 

WARNING 

– Risk of Electric Shock .  The electrical equipment must be connected only to a supply circuit that is protected by a 

ground-fault circuit-interrupter (GFCI).  Such a GFCI should be provided by the installer and should be tested on a routine basis.  To test 
the GFCI, push the test button.  The GFCI should interrupt power.  Push reset button.  Power should be restored.  If the GFCI fails to 
operate in this manner, the GFCI is defective.  If the GFCI interrupts power to the electrical equipment without the test button being 
pushed, a ground current is flowing, indicating the possibility of an electrical shock.  Do not use this electrical equipment.  Disconnect the 
electrical equipment and have the problem corrected by a qualified service representative before using.

 

 

CAUTION 

–  This pump has been evaluated for use with water only. 

 

ATTENTION - 

Cette pompe a été évalué pour une utilisation avec de l'eau seulement. 

 

 

SAVE THESE INSTRUCTIONS 

  

 

 

Содержание LifeStar MV Series

Страница 1: ...and or death This is the safety alert symbol When you see this symbol on your equipment or in this manual look for one of the following signal words and be alert to the potential for personal injury...

Страница 2: ...event excess mechanical loading on Hayward products due to system misalignment weight shock vibration and the effects of thermal expansion and contraction 6 The effect of temperature on plastic piping...

Страница 3: ...ectrical Electrical Specs Voltage Grounding and Bonding Wiring Startup Operation Prior to Start Up Starting Priming the Pump Maintenance Storage Winterization Storing Pump For Winterization Shaft Seal...

Страница 4: ...utlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material...

Страница 5: ...codes for bonding requirements WARNING Risk of Electric Shock Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verif...

Страница 6: ...to reduce friction loss Pump height locations should be as close to system level as possible and NOT to exceed 8 feet Suction lines should have continuous slope upward from lowest point in line Joint...

Страница 7: ...fittings but at least two suction outlets Avoid f entrapping suction fitting in All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electric Code...

Страница 8: ...may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding and Bo...

Страница 9: ...t be sure to add their amp loads before calculating wire and circuit breaker sizes Use the load circuit breaker as the Master On Off switch WARNING Risk of dangerous or fatal electrical shock Be sure...

Страница 10: ...close filter manual air relief valve when a steady stream of water not air or air and water is discharged from valve Failure to do so could result in severe personal injury CAUTION NEVER OPERATE THE P...

Страница 11: ...CAUTION Allowing the pump to freeze will void the warranty CAUTION Use ONLY propylene glycol as antifreeze in your system Propylene glycol is non toxic and will not damage plastic system components ot...

Страница 12: ...lts item 20 which hold the motor assembly to the pump strainer housing item 9 using a 1 2 wrench or socket 2 Slide the motor assembly out of the pump strainer housing item 9 exposing the diffuser item...

Страница 13: ...d surface facing toward the polished surface of the ceramic seat Replacing the Impeller and Diffuser See Parts Diagram on page 14 of this manual for pump component locations 11 Screw the impeller item...

Страница 14: ...er Housing Flange O Ring 1 9 HCXP3000A Pump Housing with Drain Plug 1 10 HCXP338V60 Diffuser O Ring 1 11 SPX2700Z3SSPAK4 Diffuser Screws 4 Pack 1 12 HCXP3000B Diffuser 2 5 HP 1 12 HCXP3000B2 Diffuser...

Страница 15: ...a qualified professional if the voltage is more than 10 lower than the motor nameplate voltage rating 2 Impeller jammed with debris Have a qualified repair professional open the pump and remove the de...

Страница 16: ...uding a new seal assembly Noisy Pump 1 Air leak in suction piping cavitation caused by restricted or undersized suction line or leak at any joint low water level in system and unrestricted discharge r...

Отзывы: