Maintenance 

 

 

Clean strainer basket regularly.  Do NOT strike basket to clean.  Inspect strainer cover gasket regularly and replace as necessary. 

 

Hayward pumps have self-lubricating motor bearings and shaft seals.  No lubrication is necessary. 

 

Keep motor clean.  Insure motor air vents are free from obstruction to avoid damage.  Do NOT use water to hose off motor. 

 

Occasionally, shaft seals must be replaced, due to wear or damage.  Replace with genuine Hayward seal assembly kit.  See “Shaft 
Seal Change Instructions” in this manual. 

 
Storage/Winterization 

 

 

WARNING

 –

 

Separation Hazard.  

Do not purge the system with compressed air.  Purging the 

system with compressed air can cause components to explode, with risk of severe injury or death to 
anyone nearby.  Use only a low pressure (below 5 PSI), high volume blower when air purging the pump, 
filter, or piping.

 

 
 
 

 

CAUTION

 –

 

Allowing the pump to freeze will void the warranty.

 

 

 

CAUTION

 –

 

Use ONLY propylene glycol as antifreeze in your system.  Propylene glycol is non-toxic and will not damage 

plastic system components; other anti-freezes are highly toxic and may damage plastic components in the system.

 

 

Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions 
below).  Gravity drain system as far as possible. 

 

Keep motor dry and covered during storage.  To avoid condensation/corrosion problems, do NOT cover or wrap pump with plastic 
film or bags. 

 

Storing Pump for Winterization

 

 

 

WARNING

 –

 

To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor 

before draining pump.  Failure to disconnect power may result in serious personal injury or death. 

 
 
 
 

1.

 

Drain water level below all inlets to the system. 

2.

 

Remove drain plugs and strainer cover from strainer housing.  (See Parts Diagram on page 14 of this manual for pump 
component locations.) 

3.

 

Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping. 

4.

 

Once the pump is fully drained of water, re-install the strainer cover and drain plugs.  Store pump in a dry area. 

 
 

 

Содержание LifeStar MV Series

Страница 1: ...and or death This is the safety alert symbol When you see this symbol on your equipment or in this manual look for one of the following signal words and be alert to the potential for personal injury...

Страница 2: ...event excess mechanical loading on Hayward products due to system misalignment weight shock vibration and the effects of thermal expansion and contraction 6 The effect of temperature on plastic piping...

Страница 3: ...ectrical Electrical Specs Voltage Grounding and Bonding Wiring Startup Operation Prior to Start Up Starting Priming the Pump Maintenance Storage Winterization Storing Pump For Winterization Shaft Seal...

Страница 4: ...utlets can result in an increase potential for suction entrapment as described above WARNING Failure to keep suction outlet components clear of debris such as leaves dirt hair paper and other material...

Страница 5: ...codes for bonding requirements WARNING Risk of Electric Shock Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Contact a qualified electrician if you cannot verif...

Страница 6: ...to reduce friction loss Pump height locations should be as close to system level as possible and NOT to exceed 8 feet Suction lines should have continuous slope upward from lowest point in line Joint...

Страница 7: ...fittings but at least two suction outlets Avoid f entrapping suction fitting in All electrical wiring MUST be in conformance with all applicable local codes regulations and the National Electric Code...

Страница 8: ...may overheat causing overload tripping and reduced component life If voltage is less than 90 or more than 110 of rated voltage when motor is running at full load consult power company Grounding and Bo...

Страница 9: ...t be sure to add their amp loads before calculating wire and circuit breaker sizes Use the load circuit breaker as the Master On Off switch WARNING Risk of dangerous or fatal electrical shock Be sure...

Страница 10: ...close filter manual air relief valve when a steady stream of water not air or air and water is discharged from valve Failure to do so could result in severe personal injury CAUTION NEVER OPERATE THE P...

Страница 11: ...CAUTION Allowing the pump to freeze will void the warranty CAUTION Use ONLY propylene glycol as antifreeze in your system Propylene glycol is non toxic and will not damage plastic system components ot...

Страница 12: ...lts item 20 which hold the motor assembly to the pump strainer housing item 9 using a 1 2 wrench or socket 2 Slide the motor assembly out of the pump strainer housing item 9 exposing the diffuser item...

Страница 13: ...d surface facing toward the polished surface of the ceramic seat Replacing the Impeller and Diffuser See Parts Diagram on page 14 of this manual for pump component locations 11 Screw the impeller item...

Страница 14: ...er Housing Flange O Ring 1 9 HCXP3000A Pump Housing with Drain Plug 1 10 HCXP338V60 Diffuser O Ring 1 11 SPX2700Z3SSPAK4 Diffuser Screws 4 Pack 1 12 HCXP3000B Diffuser 2 5 HP 1 12 HCXP3000B2 Diffuser...

Страница 15: ...a qualified professional if the voltage is more than 10 lower than the motor nameplate voltage rating 2 Impeller jammed with debris Have a qualified repair professional open the pump and remove the de...

Страница 16: ...uding a new seal assembly Noisy Pump 1 Air leak in suction piping cavitation caused by restricted or undersized suction line or leak at any joint low water level in system and unrestricted discharge r...

Отзывы: