Maintenance
Clean strainer basket regularly. Do NOT strike basket to clean. Inspect strainer cover gasket regularly and replace as necessary.
Hayward pumps have self-lubricating motor bearings and shaft seals. No lubrication is necessary.
Keep motor clean. Insure motor air vents are free from obstruction to avoid damage. Do NOT use water to hose off motor.
Occasionally, shaft seals must be replaced, due to wear or damage. Replace with genuine Hayward seal assembly kit. See “Shaft
Seal Change Instructions” in this manual.
Storage/Winterization
WARNING
–
Separation Hazard.
Do not purge the system with compressed air. Purging the
system with compressed air can cause components to explode, with risk of severe injury or death to
anyone nearby. Use only a low pressure (below 5 PSI), high volume blower when air purging the pump,
filter, or piping.
CAUTION
–
Allowing the pump to freeze will void the warranty.
CAUTION
–
Use ONLY propylene glycol as antifreeze in your system. Propylene glycol is non-toxic and will not damage
plastic system components; other anti-freezes are highly toxic and may damage plastic components in the system.
Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time (see instructions
below). Gravity drain system as far as possible.
Keep motor dry and covered during storage. To avoid condensation/corrosion problems, do NOT cover or wrap pump with plastic
film or bags.
Storing Pump for Winterization
WARNING
–
To avoid dangerous or fatal electrical shock hazard, turn OFF power to motor
before draining pump. Failure to disconnect power may result in serious personal injury or death.
1.
Drain water level below all inlets to the system.
2.
Remove drain plugs and strainer cover from strainer housing. (See Parts Diagram on page 14 of this manual for pump
component locations.)
3.
Disconnect pump from mounting pad, wiring (after power has been turned OFF), and piping.
4.
Once the pump is fully drained of water, re-install the strainer cover and drain plugs. Store pump in a dry area.