Master Control Panel
Timer
PCB Testing
On RELAY PCB at REMOTE J4
Step 23:
If the unit still does not run, proceed to Step 25 on Page 32.
Page 29
- Using
RED lead
of DC voltmeter at green wire on J4 and
BLACK
lead of DC voltmeter at
COM (E12). Voltmeter should read 24 VDC. Now, push RIGHT TURN button on the remote,
voltmeter should read 0 VDC
- Do the same test procedure on the
RED wire
– push LEFT TURN button on the remote,
voltmeter should read 0 VDC