background image

Aluna W/LED Kit 1/2 

IS

13110

B

IS500

230-240V~ 50/60Hz

Concord

ISO

9001

Quality

Management

ISO

14001

Environmental 

Management

             EM 539002                             FM 01687

Feilo Sylvania Europe LTD

Avis Way, Newhaven East Sussex BN9 0ED UK

www.feilosylvania.com

© Concord Lighting Limited 02.18 

68

IP

(pict. B)    mounting on prefabricated basins
 

  (allowed thickness from 5 to 45 millimeters)

 

  (B1) walls without covering

 

  (B2) walls with plastic sheet covers

 

  N.B: for this latter mounting it is necessary the ring 

 

  gasket code 4068470 placed as shown on pict. B2

flexible protective sheath Ø 25 mm

pool wall

pressure snap-in connector

gaskets

 Ø 165÷170 mm

     submersion depth

    

50/60 cm 

gasket
to be placed between wall
and plastic sheet cover

plastic sheet cover

pool wall

B1

B2

H07RN-F cable  
Ø 12 mm max - 1m length approx.

A1

A2

(pict. A)    mounting on concrete basins
 

  

  (A1) with tile covering

 

  (A2) with plastic sheet

flexible protective sheath Ø 25 mm

pressure snap-in connector

tile covering

plastering

to be sealed properly

H07RN-F cable
Ø 12 mm max - 1m length approx.

screw ring adapter

gaskets

plastic sheet cover
with Ø 165 mm hole

 

submersion depth 50/60 cm

underwater model for very low voltage - 12V DC 
underwater operation only

• glass features: plane diffusing glass - safety tempered

Important notice: Standards do not allow shunting around pool’s borders. 
The floodlight feeding cable connected to the transformer must be directly carried 
outside «zone 2» that is not less than 3.5 meters from pool border.

Instructions:

•  feeding must be done through  a safety  power (SELV) providing 12V DC stabilized 

secondary tension. The  transformer must be protected against overloadings and 
short circuit. The fitting is supplied complete with pre-installed LED lamp and pre-
wired with 5.5 meters of cable section 2x1mm

2

, according to CENELEC HD 22.16.

S1 (for AD8 water submersion). The cable and the fitting must not be tampered for 
any reason.

• recommended installation depth, 50/60 cm from basin’s edge to center line of lamp.

•  place the sheath connector upwards, inserting by simple pressure a PVC flexible 

hose, heavy type, Ø 25 mm, to protect the cable.

•  assemble as shown on pictures.

•  tighten firmly the screw ring adapter using the proper key (pict. 1).

• about 1m of loose length of cable is given to pull out the floodlight on basin’s 

edge for relamping.

•  insert by pressure the projector into the recess with the cable well wounded on it.

N.B: the floodlight must be operated only underwater

Maintenance - relamping:

•  pull out the floodlight by inserting a screw-driver in the groove (pict. 2) and bring it 

on pool border.

•  wipe it carefully before unscrewing the ring frame using the proper key code  

 

4068469 (pict.3).

•  it is essential to do a frequent cleaning of the glass and of the outer surface of the 

fixture to avoid build up of mud and dirtiness resulting in dangerous overheating 
due to obscured light and heat dissipation. Clean the glass screen carefully by 
removing limestone deposits by means of a scraper.

• Rewind the cable around the projector inserting the latter by pressure into the niche

.

Quality control

 

 

 

 

 

Should you have any complaint please get in touch with our 
company or its sales organization. Please give the number 
of your order as well as the serial number that recognizes 
the fixture.

(pict. 1)

(pict. 2)

(pict. 3)

max 

10m

MI/1726-C

 - 3

a

 ed

Отзывы: