Aluna W/LED Kit 1/2
IS
13110
B
IS500
230-240V~ 50/60Hz
Concord
ISO
9001
Quality
Management
ISO
14001
Environmental
Management
EM 539002 FM 01687
Feilo Sylvania Europe LTD
Avis Way, Newhaven East Sussex BN9 0ED UK
www.feilosylvania.com
© Concord Lighting Limited 02.18
68
IP
(pict. B) mounting on prefabricated basins
(allowed thickness from 5 to 45 millimeters)
(B1) walls without covering
(B2) walls with plastic sheet covers
N.B: for this latter mounting it is necessary the ring
gasket code 4068470 placed as shown on pict. B2
flexible protective sheath Ø 25 mm
pool wall
pressure snap-in connector
gaskets
Ø 165÷170 mm
submersion depth
50/60 cm
gasket
to be placed between wall
and plastic sheet cover
plastic sheet cover
pool wall
B1
B2
H07RN-F cable
Ø 12 mm max - 1m length approx.
A1
A2
(pict. A) mounting on concrete basins
(A1) with tile covering
(A2) with plastic sheet
flexible protective sheath Ø 25 mm
pressure snap-in connector
tile covering
plastering
to be sealed properly
H07RN-F cable
Ø 12 mm max - 1m length approx.
screw ring adapter
gaskets
plastic sheet cover
with Ø 165 mm hole
submersion depth 50/60 cm
underwater model for very low voltage - 12V DC
underwater operation only
• glass features: plane diffusing glass - safety tempered
Important notice: Standards do not allow shunting around pool’s borders.
The floodlight feeding cable connected to the transformer must be directly carried
outside «zone 2» that is not less than 3.5 meters from pool border.
Instructions:
• feeding must be done through a safety power (SELV) providing 12V DC stabilized
secondary tension. The transformer must be protected against overloadings and
short circuit. The fitting is supplied complete with pre-installed LED lamp and pre-
wired with 5.5 meters of cable section 2x1mm
2
, according to CENELEC HD 22.16.
S1 (for AD8 water submersion). The cable and the fitting must not be tampered for
any reason.
• recommended installation depth, 50/60 cm from basin’s edge to center line of lamp.
• place the sheath connector upwards, inserting by simple pressure a PVC flexible
hose, heavy type, Ø 25 mm, to protect the cable.
• assemble as shown on pictures.
• tighten firmly the screw ring adapter using the proper key (pict. 1).
• about 1m of loose length of cable is given to pull out the floodlight on basin’s
edge for relamping.
• insert by pressure the projector into the recess with the cable well wounded on it.
N.B: the floodlight must be operated only underwater
Maintenance - relamping:
• pull out the floodlight by inserting a screw-driver in the groove (pict. 2) and bring it
on pool border.
• wipe it carefully before unscrewing the ring frame using the proper key code
4068469 (pict.3).
• it is essential to do a frequent cleaning of the glass and of the outer surface of the
fixture to avoid build up of mud and dirtiness resulting in dangerous overheating
due to obscured light and heat dissipation. Clean the glass screen carefully by
removing limestone deposits by means of a scraper.
• Rewind the cable around the projector inserting the latter by pressure into the niche
.
Quality control
Should you have any complaint please get in touch with our
company or its sales organization. Please give the number
of your order as well as the serial number that recognizes
the fixture.
(pict. 1)
(pict. 2)
(pict. 3)
max
10m
MI/1726-C
- 3
a
ed