Cord Assembly Removal
Remove the bolt from the pump
housing using a 7/16" socket.
Remove the 4 screws
from the motor.
Pull the plug away from the motor.
Note: When replacing the cord assembly
clean surface thoroughly and use
new o-ring and RTV #162 White
Silicone for a water tight seal.
Step 1:
Step 2:
Step 3:
Page 44
Содержание KingShark 2 Plus
Страница 1: ...Commercial Cleaner Troubleshooting Guide 2012 Hayward Industries Inc...
Страница 36: ...Ohm Check at Motor Step 28 Ohm meter 0 9 ohms 1 3 ohms for 115 VAC 4 3 ohms 6 3 ohms for 240 VAC Page 34...
Страница 43: ...Handle Removal Step 1 Use a flat head screwdriver on both ends of the handle pin to unscrew and remove Page 41...