Master Control Panel
1.
2.
Step 25:
Page 31
1. After testing the RELAY PCB Board (Step 24), if the tests do not match the correct
voltages, then
the RELAY PCB Board will need to be replaced.
2. If the problem still exists after replacing the RELAY PCB Board, remove the cannon plug from the
master control panel. Insert the jumper wire into the 2 center ports of the connector plug at the
master control panel. Repeat steps 24 & 25. If steps 24 & 25 pass the testing, the motor and cord
need to be test separately to determine which one needs to be replaced.