USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 21 of 76
HCP3000 SERIES Variable Speed Pump
ISHCP3000VSPC Rev -B
12.
+ -
Enable or Disable Low Temp Operation
< >
Move to next menu item
13.
+ -
Use to enable or disable password protection
< >
Move to next menu item
Note
: See section 6.13 for details on Password Protection configuration.
14.
+ -
Set pump speed for Low Temp Operation
< >
Move to next menu item
15.
+ -
Set temperature to activate Low Temp Operation
< >
Move to next menu item
Note:
When the pump is stopped and the internal motor drive temperature reaches the operation temperature set
point, then the pump will prime and then run according to the set speed until the internal drive temperature
becomes 10° F higher than the temperature set point. The internal drive temperature does
not correlate to the
ambient outside temperature. Low temperature operation is
not active when the pump is being remotely controlled.
Low temperature operation is NOT intended to protect the pump, system plumbing, or pool from freezing.
If Low
Temp Operation is disabled, the speed and temperature setting screens are not shown.
16.
+ -
Use + to reset to factory default settings
< >
Use > to skip reset
17.
+ -
Confirm reset of all parameters
< >
Move to next menu item
18.
6.7 Timer Menu
Buttons
Screen Used
Comments
1.
< >
Use > to enter Timer Menu
2.
3.
+ -
Use + to change displayed timer
< >
Use > to skip to next timer
4.
+ -
Use + to rename timer
< >
Use > to set motor speed for timer
Timer Menu
Press > to enter
Timer 1
1725rpm
12:00a to 11:45p
Press + to change;
Press > next timer
T1: Timer 1
+/- rename; speed >
Low Temp Speed
1000 (600-3450rpm)
Low Temp Operation
Disabled
Reset all parameters
+ for yes; > to skip
Use Timers Menu to
set timeclocks.
Are you sure?
+ for yes; - for no
Drive Temp Setting
5ºC (41.0ºF)
Password Protection
Disabled