HCP3000 SERIES Variable Speed Pump
ISHCP3000VSPC Rev -B
6.6 Configuration Menu
Buttons
Screen Used
Comments
1.
< >
Press & hold < and > buttons for several seconds to
unlock
Configuration
Menu
2.
< >
Use > to enter Configuration Menu
3.
4.
+ -
Use + to change clock setting
< >
Use > if clock is correct
5.
+ -
Adjust day/time setting
< >
Move to next selection, then to next menu item
6.
+ -
Select whether to display speed in rpm (Revolutions
per Minute) or % of full speed
< >
Move to next menu item
7.
+ -
Set maximum running speed of pump
< >
Move to next menu item
8.
+ -
Set minimum running speed of pump
< >
Move to next menu item
9.
+ -
Select pump prime duration
< >
Move to next menu item
Note:
User may set the pump to prime at the maximum allowed speed for 0-15 minutes in 30 second increments.
10.
+ -
Select Standalone/Hayward or Relay Control
< >
Move to next menu item
Note:
See sections 5.3 and 5.4 for more detail.
11.
+ -
Select Comm Bus Address for pump
< >
Move to next menu item
Note:
The pump can be controlled by a Hayward control through the Comm Bus, or by a third party control using
relay contacts to select speeds set in the Timer Menu. When communicating with Hayward controls other than
OmniLogic, a bus address must be chosen for the pump. When communicating with OmniLogic, the Comm Bus
Address screen is not shown and the HUA (Hayward Unique Address) is used. If Relay Control is selected, the timer
speed settings are invoked when inputs 1-3 (INP1-INP3) are selected according to the table in section 5.4.
Configuration Menu
press > to enter
Set Day and Time
Thursday 1:27p
Speed Selection
rpm
MAX allowed speed
3250 (600-3450rpm)
MIN allowed speed
600 (600-3450rpm)
Prime Duration
8:00 minutes
Remote Control Mode
Standalone/Hayward
Set Comm Bus Address
Pool Filter
Configuration Menu
Locked
Time: Th 1:27PM
+ change or > skip
Use + / - to adjust,
> go to next item