USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 15 of 76
HCP3000 SERIES Variable Speed Pump
ISHCP3000VSPC Rev -B
5.3 Hayward Control Wiring (For remote control of pump speed)
Note: For software compatible Hayward controls only
Figure 5.3-1
The HCP3000 SERIES Variable Speed Pump can communicate with and be controlled by Hayward pool controls such
as OmniLogic™, ProLogic®, E-Command® 4, and OnCommand®. Minimum software revision requirements:
OmniLogic R1.0.0, ProLogic 3.00, OnCommand 1.00, E-Command 2.65, E-Command 4 2.80, AquaLogic 2.65, and
AquaPlus 2.65. To determine Hayward control software revision, consult the appropriate Hayward pool control
installation manual or visit our website at www.haywardpool.com. Connection wire must be rated for a minimum of
300V, and may be up to 500 feet in length. Use removable 2-position terminal block connector for wiring connection
to motor drive board taking care to note the wire colors and corresponding numbers next to the connectors. Do
not
connect to the upper input terminals shown as light gray above.
Once installed, Remote Control Mode must be set to Standalone/Hayward in the pump Configuration Menu (see
section 0), and for all controls other than OmniLogic, Comm Bus Address must be set according to instructions
provided in the Hayward pool control installation manual (see section 6.6.11). It is best to leave the max/min
allowed speeds in the pump configuration menu set to their factory defaults to prevent conflict with these settings in
the Hayward pool control configuration menu. Preset Speeds 1-4 and Quick Clean are disabled when the pump is
remotely controlled. Prime Duration is disabled only when the pump is communicating with a Hayward pool control.
5.4 External Relay Speed Control Wiring (For remote selection of pump speed)
Note: For third party controls and Hayward controls that are NOT software compatible.
Figure 5.4-1