4.10 Remote Control Wiring/Operation
The HCP3000 SERIES Variable Speed Pump can be controlled in a wide variety of ways as described below:
1.
Pump can operate by itself in Stand-Alone Mode using its built-in programmable timers.
2.
Pump can communicate with and be controlled by a variety of Hayward controls. See Section 5.3 for more
information regarding connecting the HCP3000 SERIES Variable Speed Pump and Hayward controls.
3.
Pump can also be controlled from third party controls (i.e. another manufacturer's control) using relay contacts.
See Section 5.4 for more information regarding connection the HCP3000 SERIES Variable Speed Pump and third
party controls.
4.11 Digital Control Interface Orientation
The Digital Control Interface can be rotated to any of four desired positions after installation by loosening the two
screws securing the user interface to the motor drive, lifting the user interface and rotating it to the desired position,
and tightening the two screws in the new position. (
Figure 4.11-1
)
Figure 4.11-1
4.12 Interface Wall Mounting
The interface can also be wall mounted using the parts supplied in the wall mount kit using the following procedure.
1.
TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER.
2.
Loosen the two screws securing the user interface to the motor drive & remove the user interface. (
Figure 4.12-1
)
3.
Disconnect the short cable that extends out from the motor drive to the user interface. (
Figure 4.12-1
)
4.
Install the blank cover, SP3200DR9, on the motor drive in the desired orientation. This cover is important to
protect internal electronics. (
Figure 4.12-2
)