6.13 Password Protection
In order to set password protection, access the configuration menu as explained in section 6.6. Use > to advance to
the Password Protection screen and follow the procedure below.
Buttons
Screen
Used
Comments
1.
+ -
Use to enable or disable password protection
< >
Move to next menu item
2.
+ -
Use to set password timeout
< >
Move to next menu item
Note: This sets the amount of time from the last button activation after the system has been unlocked to the point
where the system becomes locked again.
3.
+ -
Use change system password if desired
< >
Move to next menu item
4.
+ -
Use to set selected password character
< >
Move to next password character/next menu item
5.
+ -
Use to set selected password character
< >
Move to next password character/next menu item
Note: If the new password is not confirmed correctly, then the user will be prompted again to confirm the password.
If a mistake is made when entering the password, pressing Stop/Resume will cancel the action.
After a password has been set, follow the procedure below to unlock the system from the Home screen.
Buttons
Screen
Used
Comments
6.
+ -
Use to set selected password character
< >
Move to next password character
Note: When password protection is enabled and the timeout has elapsed, the user will be prompted to enter the
password to unlock the display when any of the display buttons (other than Stop/Resume) are selected. The user
may use Stop/Resume to stop the pump and resume normal operation without having to enter the password. The
factory default password is 1234. If the password has been changed, it may be reset to factory default by pressing
and holding the Speed 1 and Speed 4 buttons at the same time while powering on the drive, or by resetting all
parameters in the Configuration Menu. If a mistake is made when entering the password, pressing Stop/Resume will
cancel the action. If the pump is being controlled by a Hayward or third party pool control, the pump display can be
locked by the password, however, the pump will respond to any and all commands being sent from the pool control.
Password Protection
Disabled
Password Timeout
0:15
System Password
+ change or > skip
System Locked
Password: 0___
Set Password
0___
Confirm Password
0___