Within
5s
, start setting the time.
Press
SETUP
x
times. One press corresponds
to
15s
. Each pressing is signaled by the
lighting of the diode. If the button is not
pressed within these
5 seconds
, the
controller will set the default time.
SETUP
After
3s
from the last press, the
LED1
will
flash
3 times
. The controller will remember
the settings and return to normal operation.
LEAF TIME M1 to M2
If the leaves overlap, set the advance time M1 to M2. The lead-in time for closing is twice
as long as for opening. Adjust the settings so that the leaves do not collide or the
overlapping leaf does not reach the closing end position earlier than the other.
We set it in the range from 0s to 10s in 1s step. Default: 0s
Hold down the SETUP button.
SETUP
LED1
will light up and then turn off.
Release the SETUP button.
SETUP
LED1
will start blinking rapidly.
Within 5s, start setting the time.
Press SETUP
x
times. One press
corresponds to 1 second when opening and 2
seconds when closing. Each pressing is
signaled by the lighting of the diode. If the
button is not pressed within these 5s, the
controller will set the time to 0s.
SETUP
After 3s from the last press, the
LED1
diode
will flash 3 times. The controller will
remember the settings and return to normal
operation.
PROGRAMMING THE WORK OF ENGINES
The maximum operating time of the motor is 2 minutes (at full speed). The controller
makes it possible to program the release of the leaves - during this time the engine works at
a reduced speed, reaching the fully open or closed position.
ATTENTION! The limit switches can be NC or NO type.
When programming work, the controller automatically recognizes their type. If you do
not use additional limit switches, it is absolutely necessary to install mechanical stops in
the fully open and closed position. The controller automatically adds a reserve to the
programmed settings so that in the event of load changes (e.g. caused by the influence of
external temperature) the gate always reaches the fully open and closed positions.
ATTENTION! For the single-leaf gate mode (from version HELB9C REV 1.7), the items
related to the M2 leaf should be omitted during the procedure.
DEFAULT SETTINGS: