![HATO SWING 400 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/hato/swing-400/swing-400_assembly-and-operation-manual_2107301015.webp)
Set the power of the motors with the potentiometer to a value close to the minimum.
You should be aware that the maximum force of the actuators is 1600N and using the
maximum value on a delicate gate may damage it. When starting, gradually adjust the
engine power to the weight of the leaf.
4.1.
Connecting photocells
The infrared barrier is an essential security element that must be connected to the
controller. It prevents the gate from hitting a vehicle, person or object in the clear
passage. Photocells are necessary for the correct operation of the device and ensure
safety. It is required to connect a safety curtain or other additional protection against
crushing in the light of the leaves operation during closing. They must be connected in
series with the photocells.
+24VDC
– photocells power supply plus
COM
–power supply minus for the photocell receiver
FOTOCOM
–power supply minus the photocell
transmitter
COM
– photocell COM output
FOTO
IN
–NC contact of the photocell
The 24V power supply capacity of the connector is 400mA,
therefore make sure that the total power load does not exceed this
current value. An example of connecting photocells is shown in the
connection diagram.
4.2.
STOP safety connection
The NC type protections monitoring the range of the leaves should be
connected in series to the STOP and COM inputs. They are necessary for the correct
operation of the device and ensure safety.
STOP
– NC safety input
COM
– common wire
4.3.
Connection of the SBS manual control button and the WI wicket function
The connection should be made with a 2x 0.5mm cable (the cable type should
be in accordance with CEI 20-22; CEI EN50267-2-1 standards), the maximum length
of the cable depends on its electrical parameters, therefore, the following rule should
be adopted that required cable length, its resistance should not exceed 100ohm. As a
standard, the use of a cable with a cross-section of 0.5 mm and a length of not more
than 20 m is sufficient for the correct operation of the controller, for required greater
distances, 4x0.5 (mm) cables can be used by connecting the wires in parallel - in
pairs, or by increasing the cross-section of the cable (2x 1mm).
SBS
– bell button for sequence control
WI
– bell button to control the WICKET function
COM
– common wire
4.4.
Connecting the electric strike
15
Содержание SWING 400
Страница 7: ...OUTER DIMENSIONS OF THE ACTUATOR 7 ...
Страница 11: ...11 ...
Страница 19: ...If you do not use the STOP and or PHOTO inputs put on the STOP COM and or FOTO IN FOTO COM jumpers 19 ...
Страница 21: ...21 ...
Страница 35: ...35 ...