background image

4

Form No. CWBM-1120

English

IMPORTANT SAFETY INFORMATION

All Models

Hatco Refrigerated Drop-In Wells are reliable and versatile. 

Each unit has an insulated, stainless steel and aluminized 

steel housing. The sides of the internal well are completely 

surrounded with a copper evaporator coil to provide even 

chilling from top to bottom. The Refrigerated Drop-In Well is 

controlled with a digital temperature controller and a Power 

I/O (on/off) Switch housed in a single, control box. The control 

box is connected to the condensing unit with a 48″ (1219 mm) 

power cord. A 6′ (1829 mm) power cord and plug connected to 

the control box provides power to the entire unit. 
All models are designed to be mounted to the topside of 

various types of countertop material including stainless steel, 

wood, Corian, Swanstone, etc... Hatco Refrigerated Drop-In 

Wells are designed, manufactured, and tested to maintain safe 

food holding temperatures.

The 

eco

ization logo identifies products designed to reflect 

Hatco’s commitment to improving, protecting, and preserving 

the global environment. Hatco Refrigerated Drop-In Wells 

qualify for the 

eco

ization logo through the use of green-friendly 

insulation as well as a highly efficient condensing unit.
Each model of Refrigerated Drop-In Well is supplied from 

the factory with the appropriate number of 20″ (508 mm) Pan 

Support Bars, depending on the model’s pan capacity.
Each individual well is capable of holding a variety of pan 

combinations of full size, 1/2-size, 1/3-size, and/or 1/6-size 

pans with accessory Adapter Bars.
Food Pans, Pan Support Bars, Adapter Bars, and other 

accessories are available for the Refrigerated Drop-In Wells.  

Refer to the OPTIONS AND ACCESSORIES section in this 

manual for details. 

CWB-1

CWB-2

CWB-3

CWB-4

CWB-6

CWB-5

Pans Not Included

MODEL DESCRIPTION

NOTICE

Do not locate unit in area with excessive air movement 

around unit. Avoid areas that may be subject to active air 

movements or currents (i.e., near exhaust fans/hoods, air 

conditioning ducts, and exterior doors).

NOTICE

This unit is intended for commercial use only—NOT for 

household use.

Содержание CWB Series

Страница 1: ...menos que haya le do y comprendido el contenido de este manual Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio lesi n o muerte Este manual...

Страница 2: ...optimum performance Every unit is inspected and tested thoroughly prior to shipment This manual provides the installation safety and operating instructions for the Refrigerated Drop In Wells Hatco re...

Страница 3: ...rved at a safe temperature WARNING Make sure all operators have been instructed on the safe and proper use of the unit This unit is not intended for use by children or persons with reduced physical se...

Страница 4: ...tifies products designed to reflect Hatco s commitment to improving protecting and preserving the global environment Hatco Refrigerated Drop In Wells qualify for the ecoization logo through the use of...

Страница 5: ...o BS 1363 AS 3112 270 lbs 122 kg 5 8 hp 60 1956 2138 2328 8 9 9 3 9 7 CEE 7 7 Schuko BS 1363 CWB 6 5 8 hp 120 60 800 8 7 NEMA 5 15P 313 lbs 142 kg 1 2 hp 220 230 240 50 826 904 984 3 8 3 9 4 1 CEE 7 7...

Страница 6: ...5 1143 mm 27 686 mm 25 1 2 648 mm 12 305 mm SPECIFICATIONS D C A Front View Model CWB 6 Side View Model CWB 6 B 2 3 4 70 mm Dimensions Refrigerant Information Hatco Refrigerated Drop In Wells use R 51...

Страница 7: ...ntil the unit and the installation site are completely prepared for the unit to be installed 1 Remove all external packaging from the unit 2 Remove tape protective packaging and literature from all su...

Страница 8: ...installed in the openings to protect the condensing unit Openings should be a minimum of 12 x 12 31 x 31 cm or 144 square inches 961 square cm One opening should be located in front of the condenser...

Страница 9: ...ol box in a horizontal surface may result in the collection of liquids and lead to electric shock 1 Cut and drill the appropriate holes in the mounting surface Refer to the Control Box Cutout and Scre...

Страница 10: ...digital temperature controller will energize and ON will appear on the display followed by the current temperature of the unit The symbol on the display will illuminate to show the condensing unit is...

Страница 11: ...y until the number 22 appears on the display then press the key 4 Use the or key to scroll through the programmable parameters until dI defrost interval appears on the display 5 Press the key to selec...

Страница 12: ...ld detergent Use a plastic scouring pad to remove any hardened food particles or mineral deposits 4 Wipe down well with a clean sanitized cloth to remove the detergent residue Repeat until all deterge...

Страница 13: ...ve noise and vibration when turned on Internal components have not been adequately warmed before operation Turn off unit immediately Unit should be stored in a warm environment of 65 F 18 C for at lea...

Страница 14: ...Pan 2 1 2 64 mm Deep Full Pan 4 102 mm Deep Full Pan 6 152 mm Deep Stainless Steel Food Pans False Bottom False bottoms are accessories available for all models False bottoms allow better drainage fo...

Страница 15: ...nt caused by liming sediment buildup chemical attack or freezing or Product misuse tampering or misapplication improper installation or application of improper voltage 2 LIMITATION OF REMEDIES AND DAM...

Страница 16: ...e et d essais pratiques Les mat riaux utilis s ont t s lectionn s pour une durabilit maximale une apparence attractive et des performances optimales Chaque appareil est soigneusement inspect et test...

Страница 17: ...erie et en lectricit AVERTISSEMENT Assurez vous que les aliments ont t correctement r frig r s une temp rature appropri e avant de les placer dans l appareil Maintenir des aliments une temp rature ina...

Страница 18: ...a sortie de l usine avec le nombre ad quat de barres de support de bacs de 20 508 mm en fonction de la contenance des bacs du mod le Chaque cuve peut accueillir diff rentes combinaisons de bacs de gra...

Страница 19: ...chuko BS 1363 CWB 6 5 8 hp 120 60 800 8 7 NEMA 5 15P 142 kg 313 lbs 1 2 hp 220 230 240 50 826 904 984 3 8 3 9 4 1 CEE 7 7 Schuko BS 1363 AS 3112 142 kg 313 lbs 5 8 hp 60 1956 2138 2328 8 9 9 3 9 7 CEE...

Страница 20: ...globale C Hauteur de la cuve D CWB 1 483 mm 19 686 mm 27 648 mm 25 1 2 305 mm 12 CWB 2 813 mm 32 686 mm 27 648 mm 25 1 2 305 mm 12 CWB 3 1143 mm 45 686 mm 27 648 mm 25 1 2 305 mm 12 CARACT RISTIQUES T...

Страница 21: ...r dans le groupe compresseur condenseur pourrait entra ner une panne de l appareil et aurait pour effet d annuler la garantie AVIS Maintenez l appareil dans la position verticale lors du transport et...

Страница 22: ...h ssis du groupe compresseur condenseur sur l enceinte de la cuve 5 l aide des deux boulons du panneau de contr le refixez le panneau de contr le sur le ch ssis du groupe compresseur condenseur Groupe...

Страница 23: ...tallez pas le panneau de contr le devant les serpentins du condenseur Le panneau de contr le peut tre install une distance inf rieure 1219 mm 48 du groupe compresseur condenseur 4 Connectez le raccord...

Страница 24: ...mensions de d coupe 2 Retirez le bo tier de commande de l unit en retirant les boulons sur le c t du groupe de condensation 3 Retirez les quatre vis du couvercle du bo tier de commandes et retirez le...

Страница 25: ...est activ et refroidit la cuve NOTA Cet appareil est pr r gl la sortie de l usine une temp rature nominale de 0 C 32 F Si les conditions ambiantes n cessitent un r glage de la temp rature nominale re...

Страница 26: ...ran Pour la premi re mise en service de l appareil ce nombre sera O 6 Appuyez sur la touche ou dans les 60 secondes pour faire d filer le nombre d heures souhait entre chaque cycle de d givrage Voici...

Страница 27: ...ticule solide de nourriture ou d p t de min raux 4 Essuyez la cuve l aide d un chiffon propre et d sinfect pour enlever toute trace de d tergent R p tez l op ration jusqu ce qu il n y ait plus aucune...

Страница 28: ...avant la mise en service teignez imm diatement l appareil L appareil doit tre stock dans un environnement chaud une temp rature de 65 F 18 C pendant au moins 10 heures OFF clignote sur l cran de comm...

Страница 29: ...profondeur largeur x profondeur x hauteur 12 3 4 x 20 3 4 x 4 324 x 527 x 102 mm HDW 6 PAN Bac en acier inoxydable grande taille 6 152 mm de profondeur largeur x profondeur x hauteur 12 3 4 x 20 3 4 x...

Страница 30: ...dition 2 Appliquez un agent d tanch it base de silicone homologu par la NSF sur les bords de l appareil pour le fixer la base inclin e 3 Appliquez un agent d tanch it base de silicone homologu par la...

Страница 31: ...VETS OU TOUTES AUTRES ATTEINTES AUX DROITS DE LA PROPRI T INTELLECTUELLE Sans restreindre la port e g n rale des nonc s pr c dents CES GARANTIES NE COUVRENT PAS LES L MENTS SUIVANTS ampoules d clairag...

Страница 32: ...uis 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfiel...

Отзывы: