Harvia WHP1500 Скачать руководство пользователя страница 6

6

EN

RU

Ýëåìåíòû äûìîõîäà ñîåäèíÿþòñÿ ìåæäó ñîáîé ñïîñîáîì, 
óêàçàííûì íà ñåðèè ðèñóíêîâ. Ïðåäâàðèòåëüíî ñ 
îñíîâíîãî ìîäóëÿ ñíèìàåòñÿ âåðõíèé òîðöîâûé ýëåìåíò, 
êîòîðûé â êîíöå ìîíòàæà óñòàíàâëèâàåòñÿ íà âåðõíèé 
äîïîëíèòåëüíûé ìîäóëü. Ìîíòàæ îñóùåñòâëÿåòñÿ 
ñëåäóþùèì îáðàçîì: âíóòðåííÿÿ ÷àñòü äûìîõîäà 
ïðèêðó÷èâàåòñÿ ê ïðåäûäóùåìó ýëåìåíòó, çàòåì íà íåå 
óñòàíàâëèâàåòñÿ è ïðèæèìàåòñÿ âíåøíÿÿ ðóáàøêà ñ 

èçîëÿöèîííûì ìàòåðèàëîì, è â êîíöå 
âíåøíÿÿ ðóáàøêà çàêðåïëÿåòñÿ ñ 
ïîìîùüþ øóðóïîâ.

A. Âíóòðåííÿÿ ÷àñòü ïðèñîåäèíÿåìîãî 
ìîäóëÿ èçâëåêàåòñÿ èç èçîëÿöèîííîãî 
ñëîÿ è âíåøíåé ðóáàøêè.

B. Ïàçû ñîåäèíÿåìîé âíóòðåííåé 
òðóáû ïîäãîíÿþòñÿ ïîä øèïû 
âíóòðåííåé ÷àñòè, íàõîäÿùåéñÿ âíèçó. 
Ýëåìåíò ïðîêðó÷èâàåòñÿ ïî ÷àñîâîé 
ñòðåëêå äî ïîëíîãî çàòÿãèâàíèÿ ìåñòà 
ñîåäèíåíèÿ è äî ïîëíîé îñòàíîâêè.

C. Âíåøíÿÿ ðóáàøêà ñ èçîëÿöèîííûì 
ìàòåðèàëîì óñòàíàâëèâàþòñÿ íà 
âíóòðåííþþ ÷àñòü. Ïàçû ñîåäèíÿåìîé 
âíåøíåé ðóáàøêè ïîäãîíÿþòñÿ ïîä 
øèïû âíåøíåé ðóáàøêè, íàõîäÿùåéñÿ 
âíèçó. Ýëåìåíò ïðîêðó÷èâàåòñÿ 
ïî ÷àñîâîé ñòðåëêå äî ïîëíîãî 
çàòÿãèâàíèÿ ìåñòà ñîåäèíåíèÿ è äî 
ïîëíîé îñòàíîâêè.

D. Äëÿ óïëîòíåíèÿ âîçìîæíûõ çàçîðîâ 
ìåæäó ñëîÿìè èçîëÿöèè ðàçíûõ 
ýëåìåíòîâ íà èçîëÿöèîííûé ìàòåðèàë 
íåîáõîäèìî íàäàâèòü ñâåðõó.

E. Âíåøíÿÿ ðóáàøêà çàêðåïëÿåòñÿ 
òðåìÿ øóðóïàìè-ñàìîðåçàìè. 
Øóðóïû óñòàíàâëèâàþòñÿ â ðóáàøêó â 
ìåñòå óãëóáëåíèé.

F. Âåðõíèé òîðöîâûé ýëåìåíò 
çàêðåïëÿåòñÿ òðåìÿ øóðóïàìè-
ñàìîðåçàìè. Øóðóïû ïðîõîäÿò ñêâîçü 

ðóáàøêó. 

ÂÍÈÌÀÍÈÅ! Âåðõíèé òîðöîâûé 

ýëåìåíò äîëæåí áûòü óñòàíîâëåí 
òàêèì îáðàçîì, ÷òîáû øóðóïû 
ïîïàëè â ðåáðî æåñòêîñòè, 
îáðàçóåìîå ïàçàìè âåðõíåé 
ðóáàøêè.

A. Pull the smoke pipe 

of the component/

extension out of the 

insulation and the outer 

casing.

B. Join the pipe by 

slotting it to the studs 

of the smoke pipe 

below. Turn clockwise 

until the joint tightens 

and the pipe is fixed.

C. Press the outer 

casing with the 

insulation on the smoke 

pipe. Slot the studs in 

the outer casing below. 

Turn clockwise until the 

joint tightens and the 

pipe is fixed.

D. Any gaps between 

the insulation sheets 

should be sealed 

by pressing them 

downwards in the pipe.

E. Lock the outer casing 

in place with three self-

boring screws. Bore 

the screws through the 

metal sockets.

F. Join the upper end 

with three self-boring 

screws. Bore the 

screws through the 

plate. 

NOTE! The upper end 

should be installed in 

a position where the 

screws will meet with 

the slot-braced outer 

casing.

3. Connecting the parts of the Steel Chimney

The components of the steel chimney are joined 

by following the instructions in the pictures. The 

leading principle is to lock the smoke pipe to the 

former component by winding it in place, then 

pressing the outer casing with insulation on the 

smoke pipe and finally locking the casing in place 

with screws.

F

A

B

E

C

D

3. Ñîåäèíåíèå ýëåìåíòîâ äûìîõîäà ìåæäó ñîáîé

Содержание WHP1500

Страница 1: ...07032006H Instructions for installation of Steel Chimney Steel Chimney EN RU Harvia Oy PL12 40951 Muurame Finland www harvia fi...

Страница 2: ...Standard delivery Steel Chimney extensions WHP500 Length 0 5 m Length of isolated component 470 mm 0 5 470 Steel Chimney 1 5 m 1 5 Smoke pipe 1 0 m stainless steel 1 0 Lead through flange Note Extens...

Страница 3: ...el Chimney 6 4 Installing the rain flange 7 5 Installing the rain cap 8 6 Installing the lead through flange 8 1 4 2 5 3 6 4 7 5 8 6 8 EN RU 0809 Harvia Oy PL 12 40951 Muurame Finland 06 0809 CPD 0548...

Страница 4: ...ere is no need for protection if the chimney is installed in a sauna The chimney shouldn t be encapsulated The maximum height of the steel chimney is five metres while the permissible maximum for the...

Страница 5: ...nces from the mounting instructions In case the protective distance requirements for the furnace are higher than for the chimney the distance can be reduced by installing non flammable protective plat...

Страница 6: ...nwards in the pipe E Lock the outer casing in place with three self boring screws Bore the screws through the metal sockets F Join the upper end with three self boring screws Bore the screws through t...

Страница 7: ...e chimney on the surface of the roof Soap solution can be used as a lubricant if needed C Mould the brims of the rain flange carefully fitting it to the roof profile D Spread some silicone underneath...

Страница 8: ...ng the lead through flange The two piece lead through flange fixed in horizontal or pitched ceilings trims the edges of the opening The lead through flange is best suited for roof pitches of under 1 1...