 WHP1000

Length: 1.0 m

Length of isolated 

component: 970 mm

Äëèíà 1,0 

ì

Äëèíà èçîëèðîâàííîãî 
÷àñòè 970 ìì

Rain cap

Îãîëîâîê

Rain flange

Äîæäåâîé ôëàíåö

WHP1500

Standard delivery

Ñòàíäàðòíàÿ êîìïëåêòàöèÿ

Steel Chimney extensions

Äîïîëíèòåëüíûå ìîäóëè

 WHP500

Length: 0.5 m

Length of isolated 

component: 470 mm

Äëèíà 0,5 

ì

Äëèíà èçîëèðîâàííîãî 
÷àñòè 470 ìì

Steel Chimney 1.5 m

Äûìîõîä ñòàëüíîé 1,5 ì

Smoke pipe 1.0 m

(stainless steel)

Äûìîâàÿ òðóáà 1,0 ì 

(ïîëèðîâàííàÿ íåðæàâåþùàÿ ñòàëü)

Lead-through flange

Ïðîõîäíîé ôëàíåö

Note! Extensions increase the total length of the steel 

chimney by the length of their isolated component.

Âíèìàíèå! Äîïîëíèòåëüíûå ìîäóëè óâåëè÷èâàþò ïîëíóþ 
äëèíó ñòàëüíîãî äûìîõîäà íà äëèíó ñâîåé èçîëèðîâàííîé 
÷àñòè.

Содержание WHP1500

Страница 1: ...07032006H Instructions for installation of Steel Chimney Steel Chimney EN RU Harvia Oy PL12 40951 Muurame Finland www harvia fi...

Страница 2: ...Standard delivery Steel Chimney extensions WHP500 Length 0 5 m Length of isolated component 470 mm 0 5 470 Steel Chimney 1 5 m 1 5 Smoke pipe 1 0 m stainless steel 1 0 Lead through flange Note Extens...

Страница 3: ...el Chimney 6 4 Installing the rain flange 7 5 Installing the rain cap 8 6 Installing the lead through flange 8 1 4 2 5 3 6 4 7 5 8 6 8 EN RU 0809 Harvia Oy PL 12 40951 Muurame Finland 06 0809 CPD 0548...

Страница 4: ...ere is no need for protection if the chimney is installed in a sauna The chimney shouldn t be encapsulated The maximum height of the steel chimney is five metres while the permissible maximum for the...

Страница 5: ...nces from the mounting instructions In case the protective distance requirements for the furnace are higher than for the chimney the distance can be reduced by installing non flammable protective plat...

Страница 6: ...nwards in the pipe E Lock the outer casing in place with three self boring screws Bore the screws through the metal sockets F Join the upper end with three self boring screws Bore the screws through t...

Страница 7: ...e chimney on the surface of the roof Soap solution can be used as a lubricant if needed C Mould the brims of the rain flange carefully fitting it to the roof profile D Spread some silicone underneath...

Страница 8: ...ng the lead through flange The two piece lead through flange fixed in horizontal or pitched ceilings trims the edges of the opening The lead through flange is best suited for roof pitches of under 1 1...

Отзывы: