iv
HARTING Electric GmbH
Ha-VIS RF-R500 - Assembly Manual
English
Figures
Figure 1
Installation drawing .....................................................................................................................................4
Figure 2
Connection Overview .................................................................................................................................5
Figure 3
External antenna connection ANT1-4 and X1 for the power supply ...........................................................6
Figure 4
Connection for the power supply ................................................................................................................6
Figure 5
LAN and PoE connection ...........................................................................................................................7
Figure 6
USB-Interface for host communication .......................................................................................................8
Figure 7
USB-Interface for external WLAN interface ................................................................................................9
Figure 8
RS 232 interface pin-outs on X6.................................................................................................................9
Figure 9
Wiring example for connecting the RS 232 interface ...............................................................................10
Figure 10
RS 485 interface pin-outs on X6...............................................................................................................10
Figure 11
Optocoupler pin-outs IN1 – IN5 ................................................................................................................ 11
Figure 12
Internal and possible external wiring of the optocouplers......................................................................... 11
Figure 13
Optocoupler outputs OUT1-2 ...................................................................................................................12
Figure 14
Internal and possible external wiring of the optocoupler outputs OUT1-2 ................................................13
Figure 15
Relay output pin-outs REL1-3 ..................................................................................................................13
Figure 16
Internal and possible external wiring of the relay output ..........................................................................14
Figure 17
Position of the reset switches T1 and T2 ..................................................................................................16
Figure 18
Equipment Classification according to ETSI EN 301 489: Class 2
..........................................................19
Tables
Table 1
Reader types ..............................................................................................................................................3
Table 2
Optional reader accessorie.........................................................................................................................3
Table 3
Connection terminals ..................................................................................................................................5
Table 4
Push button function ...................................................................................................................................5
Table 5
External antenna connection ......................................................................................................................5
Table 6
Pin assignment for power supply................................................................................................................6
Table 7
Maximum cable length if PoE is used.........................................................................................................8
Table 8
Standard factory configuration of the Ethernet connection
.........................................................................8
Table 9
Successfully tested WLAN sticks ...............................................................................................................9
Table 10
RS 485 interface pin-outs .........................................................................................................................10
Table 11
Required external series resistor R
ext
.......................................................................................................12
Table 12
Configuration of the status LEDs
..............................................................................................................16
Table 13
Calculation of the output power ................................................................................................................17
Содержание Ha-VIS RF-R500
Страница 2: ...ii HARTING Electric GmbH...
Страница 34: ...26 HARTING Electric GmbH Ha VIS RF R500 Assembly Manual English...
Страница 35: ...i Ha VIS RF R500 1 0 Ha VIS RF R500 RFID...
Страница 43: ...3 Ha VIS RF R500 1 0 2 RFID 1...
Страница 45: ...5 Ha VIS RF R500 1 0 3 ANT1 4 X1 3 1 1 X1 DC24V X1 X1 1 VDC Vcc DC24V 5 X1 2 GND 6 4 PoE Ha VIS RF R500 p PoE...
Страница 50: ...10 HARTING Electric GmbH Ha VIS RF R500 3 3 X5 X5 11 IN1 IN5 12 X5 IN1 5 LED 500 10V 20mA 11 11 Uext...
Страница 52: ...12 HARTING Electric GmbH Ha VIS RF R500 14 OUT1 2 DC24V 30mA 3 4 2 X5 X5 3 15 REL1 3...
Страница 53: ...13 Ha VIS RF R500 1 0 DC24V 2A 1A 16...
Страница 64: ...www HARTING com...