8
HARTING Electric GmbH
Ha-VIS RF-R500 - Assembly Manual
English
Depending on the cable cross-section the following cable distances can be used.
Cable cross-section (Cat. 5 ... 7)
Maximum cable length for PoE
0.4 mm
≈ 30 m
0.6 mm
≈ 70 m
Table 7
Maximum cable length if PoE is used
3.2.2 Ethernet-Interface on X2 (10/100Tbase)
The Reader has an integrated 10/100Base-T network port for an RJ45. Connection is made on
X2 and has an automatic “Crossover Detection” according to the 100Base-T Standard.
With structured cabling Cat. 5 cables should be used. This ensures a reliable operation at
10 Mbps or 100 Mbps.
The prerequisite for using TCP/IP protocol is that each device has a unique address on the
network. All Readers have a factory set IP address.
Network
Address
IP address
192.168.10.10
Subnet-Mask
255.255.255.0
Port
10001
DHCP
AUS
Table 8
Standard factory configuration of the Ethernet connection
Note
The Reader includes a DHCP-able TCP/IP interface.
3.2.3 USB-Interface X3 (Host Communication)
The USB socket on the board is terminal X3. The pinout is standardized. The data rate is
reduced to 12 Mbit (USB full speed). A standard USB-cable can be used.
Figure 6
USB-Interface for host communication
Note
The length of the USB-cable can be a max. of 5 m (20 inch). It is not allowed to use longer
cables.
Содержание Ha-VIS RF-R500
Страница 2: ...ii HARTING Electric GmbH...
Страница 34: ...26 HARTING Electric GmbH Ha VIS RF R500 Assembly Manual English...
Страница 35: ...i Ha VIS RF R500 1 0 Ha VIS RF R500 RFID...
Страница 43: ...3 Ha VIS RF R500 1 0 2 RFID 1...
Страница 45: ...5 Ha VIS RF R500 1 0 3 ANT1 4 X1 3 1 1 X1 DC24V X1 X1 1 VDC Vcc DC24V 5 X1 2 GND 6 4 PoE Ha VIS RF R500 p PoE...
Страница 50: ...10 HARTING Electric GmbH Ha VIS RF R500 3 3 X5 X5 11 IN1 IN5 12 X5 IN1 5 LED 500 10V 20mA 11 11 Uext...
Страница 52: ...12 HARTING Electric GmbH Ha VIS RF R500 14 OUT1 2 DC24V 30mA 3 4 2 X5 X5 3 15 REL1 3...
Страница 53: ...13 Ha VIS RF R500 1 0 DC24V 2A 1A 16...
Страница 64: ...www HARTING com...