6
HARTING Electric GmbH
Ha-VIS RF-R500 - Assembly Manual
English
Figure 3
External antenna connection ANT1-4 and X1 for the power supply
3.1.1 Power supply connection on X1
The supply voltage of 24 V DC has to be connected to Terminal X1.
Terminal
Abbreviation
Description
X1 / Pin 1
VDC
Vcc – supply voltage 24 V DC ±5 %
X1 / Pin 2
GND
Ground – supply voltage
Table 6
Pin assignment for power supply
Figure 4
Connection for the power supply
ATTENTION
An operation of an Ha-VIS RF-R500-p via an external power supply and Power over Ethernet
(PoE) at the same time can cause interferences during operation.
A power supply via PoE and over an external power supply at the same time is not
recommended.