Chapter 1
Introduction
26
©2011 Harris Corporation. All rights reserved.
Storage
NEXIO AMP can be connected to storage via direct Fibre Channel, NX1000MIOH,
NX1010MIOH, or NX1011MIOH. For more information, contact your
Harris Sales
Representative
.
RAID
Redundancy
The following table describes NEXIO AMP RAID redundancy specifications.
*
Requires 2 SANs with identical configuration and capacity.
Timecode
Connection
Options
The following list describes the timecode connections options for NEXIO AMP.
RS-232
TCP/IP
Leitch clock interface
VITC reader, writer, and generator
Table 1-11
RAID Redundancy Specifications
Controller
RAIDsoft™ software RAID management
system
RAID Protection Schemes
Per Volume
RAID-3 (single drive parity; single drive
failure protection)
-OR-
ECC (multiple drive parity; dual drive
failure protection)
Intrinsic Mirroring
Protection Scheme (if
configured in your system)
Choice of RAID-3 or ECC storage
protection plus fully mirrored storage
area networks*
NEXIO Farad RAID-601
RAID 6 (drive protection) + RAID 0
(striping by NEXIO's RAIDsoft to add
bandwidth) + Intrinsic Mirroring